Back to Search Start Over

Hygrothermal assessment of north-facing, cold attic spaces under the eaves with varying structural roof scenarios

Authors :
Jensen, Nickolaj Feldt
Bjarløv, Søren Peter
Johnston, Christopher Just
Pold, Casper Fabian Hillestrøm
Hjorslev Hansen, Morten
Peuhkuri, Ruut Hannele
Jensen, Nickolaj Feldt
Bjarløv, Søren Peter
Johnston, Christopher Just
Pold, Casper Fabian Hillestrøm
Hjorslev Hansen, Morten
Peuhkuri, Ruut Hannele
Source :
Jensen , N F , Bjarløv , S P , Johnston , C J , Pold , C F H , Hjorslev Hansen , M & Peuhkuri , R H 2020 , ' Hygrothermal assessment of north-facing, cold attic spaces under the eaves with varying structural roof scenarios ' , Journal of Building Physics , vol. 44 , no. 1 , pp. 3-36 .
Publication Year :
2020

Abstract

The objective of this study was to test whether compliance with the current Danish best practice recommendations concerning design of the cold attic space will prevent damaging moisture levels. The project was performed as a full-scale experimental setup in the cool temperate climate of Denmark. The setup comprised 18 north-facing attic spaces with varying ventilation principles and varying infiltration scenarios. The relative humidity and temperature were measured in attic spaces, indoor and outdoor, for almost 3 years. The hygrothermal performance of the attics was evaluated by post-processing and comparing the data with predicted mould growth risk and with visual observations of mould growth. The results showed that following the recommended passive ventilation strategies made the hygrothermal performance in attics with diffusion-open roofing underlay worse. In addition, increasing vapour diffusion tightness of the roofing underlay made the hygrothermal performance of the cold attic spaces under the eaves worse, except for attics with passive ventilation but without infiltration. The hygrothermal performance of the attics with diffusion-tight roofing underlay was poor when combining infiltration and the assessed ventilation strategy. The performance of the same attic without infiltration showed that some degree of ventilation was needed. External roof insulation did not significantly improve the hygrothermal performance of the attic.

Details

Database :
OAIster
Journal :
Jensen , N F , Bjarløv , S P , Johnston , C J , Pold , C F H , Hjorslev Hansen , M & Peuhkuri , R H 2020 , ' Hygrothermal assessment of north-facing, cold attic spaces under the eaves with varying structural roof scenarios ' , Journal of Building Physics , vol. 44 , no. 1 , pp. 3-36 .
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1280589434
Document Type :
Electronic Resource