Back to Search Start Over

Performance of a scroll compressor with vapor-injection and two-stage reciprocating compressor operating under extreme conditions

Authors :
Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials
Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica
Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
Secretaría de Educación Superior, Ciencia, Tecnología e Innovación, Ecuador
Tello Oquendo, Fernando Mauricio
Navarro-Peris, Emilio
Gonzálvez Maciá, José
Corberán Salvador, José Miguel
Universitat Politècnica de València. Escuela Técnica Superior de Ingenieros Industriales - Escola Tècnica Superior d'Enginyers Industrials
Universitat Politècnica de València. Instituto de Ingeniería Energética - Institut d'Enginyeria Energètica
Universitat Politècnica de València. Escuela Técnica Superior de Ingeniería del Diseño - Escola Tècnica Superior d'Enginyeria del Disseny
Secretaría de Educación Superior, Ciencia, Tecnología e Innovación, Ecuador
Tello Oquendo, Fernando Mauricio
Navarro-Peris, Emilio
Gonzálvez Maciá, José
Corberán Salvador, José Miguel
Publication Year :
2016

Abstract

The current paper presents a comparative study between a scroll compressor with vapor-injection (SCVI) and a two-stage reciprocating compressor (TSRC) operating under extreme conditions. The present work is divided into two parts: in the first part, both compressors are compared in terms of compressor efficiency, volumetric efficiency, coefficient of performance (COP), and cooling capacity with R407C refrigerant; in the second part, the seasonal performances of both compressors working in cooling and heating modes are estimated and analyzed. Results show that the SCVI presents better efficiency and COP than the TSRC for pressure ratios below 7.5. This compressor can be used in air conditioning systems and heat pumps which work under moderate temperature conditions. For higher pressure ratios, the TSRC has better efficiency which subsequently gives higher COP. This type of compressor is more suited to be used in sanitary hot water systems operating in harsh climates and in low-temperature freezing systems (under −20°C).

Details

Database :
OAIster
Notes :
TEXT, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1273090453
Document Type :
Electronic Resource