Back to Search Start Over

Relating anatomical variations and patient features with dose-reconstruction accuracy of a 3D dose-reconstruction approach using CT scans of recently-treated children

Authors :
Wang, Z. (Ziyuan)
Virgolin, M. (Marco)
Dijk, van, I.W.E.M. (Irma)
Wiersma, J. (Jan)
Ronckers, C.M. (Cécile)
Oldenburger, F. (Foppe)
Balgobind, B.V. (Brian)
Rasch, C.R.N. (Coen)
Bosman, P.A.N. (Peter)
Bel, A. (Arjan)
Alderliesten, T. (Tanja)
Wang, Z. (Ziyuan)
Virgolin, M. (Marco)
Dijk, van, I.W.E.M. (Irma)
Wiersma, J. (Jan)
Ronckers, C.M. (Cécile)
Oldenburger, F. (Foppe)
Balgobind, B.V. (Brian)
Rasch, C.R.N. (Coen)
Bosman, P.A.N. (Peter)
Bel, A. (Arjan)
Alderliesten, T. (Tanja)
Publication Year :
2017

Abstract

Purpose Reconstructing 3D dose distributions for pre-1990 pediatric 2D radiotherapy plans is challenging, but key to research on late adverse effects. We studied the relation between dosimetric accuracy, anatomical variation, and other patient features of a 3D dose-reconstruction approach using CT scans of recently-treated patients, rather than phantoms. Materials and methods CT-scans of 22 Wilms’ tumor patients (age:2.5-5.3yrs; n boys/girls:11/11) treated between 2004 and 2015 were included. Two clinical plans as applied to a 4-year-old boy and girl with a left-sided Wilms’ tumor served as references. Each plan was applied to the CT scans of the other 21 patients, adjusted to correct for anatomical differences as visible in digitally-reconstructed-radiographs, and the resulting dose was calculated. Deviations in reconstructed dose, with respect to the reference dose, in organs-at-risk (spinal cord, right kidney, liver, and spleen) were characterized by the mean dose error normalized by the prescribed dose (DEmean). Deviations in organs’ location relative to a reference point (\Delta O_loc) and in organs’ shape captured by the Dice coefficient (DC) were calculated. We estimated the Pearson’s correlation between DEmean, on the one hand, and O­loc, DC, gender, age, height, and weight, on the other hand. Results Average(range) DEmean values were: spinal cord:3(0-8)%; right kidney:6(0-20)%; liver:9(0-20)%; and spleen:23(0-80)%. DC and DEmean in the right kidney were moderately negatively correlated (r2=0.41). DEmean in the liver was uncorrelated with any of the tested parameters. A positive correlation was found between Oloc and DEmean in the spleen (r2=0.68). No correlations (r2<0.2) were found between DEmean and gender, age, height, and weight. Conclusions The dose-reconstruction accuracy is primarily related to similarity in internal anatomy and not to patient features like height and weight. For a dose-reconstruction approach utilizing CT scans of recent patients

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1251876955
Document Type :
Electronic Resource