Back to Search Start Over

Optimization of a Diamond Nitrogen Vacancy Centre Magnetometer for Sensing of Biological Signals

Authors :
Webb, James L.
Troise, Luca
Hansen, Nikolaj W.
Achard, Jocelyn
Brinza, Ovidiu
Staacke, Robert
Kieschnick, Michael
Meijer, Jan
Perrier, Jean-Francois
Berg-Sørensen, Kirstine
Huck, Alexander
Andersen, Ulrik Lund
Webb, James L.
Troise, Luca
Hansen, Nikolaj W.
Achard, Jocelyn
Brinza, Ovidiu
Staacke, Robert
Kieschnick, Michael
Meijer, Jan
Perrier, Jean-Francois
Berg-Sørensen, Kirstine
Huck, Alexander
Andersen, Ulrik Lund
Source :
Webb , J L , Troise , L , Hansen , N W , Achard , J , Brinza , O , Staacke , R , Kieschnick , M , Meijer , J , Perrier , J-F , Berg-Sørensen , K , Huck , A & Andersen , U L 2020 , ' Optimization of a Diamond Nitrogen Vacancy Centre Magnetometer for Sensing of Biological Signals ' , Frontiers in Physics , vol. 8 , 522536 .
Publication Year :
2020

Abstract

Sensing of signals from biological processes, such as action potential propagation in nerves, are essential for clinical diagnosis and basic understanding of physiology. Sensing can be performed electrically by placing sensor probes near or inside a living specimen or dissected tissue using well-established electrophysiology techniques. However, these electrical probe techniques have poor spatial resolution and cannot easily access tissue deep within a living subject, in particular within the brain. An alternative approach is to detect the magnetic field induced by the passage of the electrical signal, giving the equivalent readout without direct electrical contact. Such measurements are performed today using bulky and expensive superconducting sensors with poor spatial resolution. An alternative is to use nitrogen vacancy (NV) centers in diamond that promise biocompatibilty and high sensitivity without cryogenic cooling. In this work we present advances in biomagnetometry using NV centers, demonstrating magnetic field sensitivity of similar to 100 pT/root Hz in the DC/low frequency range using a setup designed for biological measurements. Biocompatibility of the setup with a living sample (mouse brain slice) is studied and optimized, and we show work toward sensitivity improvements using a pulsed magnetometry scheme. In addition to the bulk magnetometry study, systematic artifacts in NV-ensemble widefield fluorescence imaging are investigated.

Details

Database :
OAIster
Journal :
Webb , J L , Troise , L , Hansen , N W , Achard , J , Brinza , O , Staacke , R , Kieschnick , M , Meijer , J , Perrier , J-F , Berg-Sørensen , K , Huck , A & Andersen , U L 2020 , ' Optimization of a Diamond Nitrogen Vacancy Centre Magnetometer for Sensing of Biological Signals ' , Frontiers in Physics , vol. 8 , 522536 .
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1250229247
Document Type :
Electronic Resource