Adenosine usage during AF ablation in Europe and selected long-term findings from the ESC-EHRA EORP Atrial Fibrillation Ablation Long-Term registry.

Authors :
van Rosmalen, Frank
Delhaas, Tammo
Dagres, Nikolaos
Arbelo, Elena
Blomström-Lundqvist, Carina
Crijns, Harry J G M
Da Costa, Antoine
Pytkowski, Mariusz
Sharikov, Nikita
Laroche, Cécile
Tavazzi, Luigi
Brugada, Joseph
Pison, Laurent
van Rosmalen, Frank
Delhaas, Tammo
Dagres, Nikolaos
Arbelo, Elena
Blomström-Lundqvist, Carina
Crijns, Harry J G M
Da Costa, Antoine
Pytkowski, Mariusz
Sharikov, Nikita
Laroche, Cécile
Tavazzi, Luigi
Brugada, Joseph
Pison, Laurent
Publication Year :
2021

Abstract

BACKGROUND: Adenosine can be used to reveal dormant pulmonary vein (PV) conduction after PV isolation (PVI). This study presents a subanalysis of real-world 1-year follow-up data from the ESC-EHRA EORP Atrial Fibrillation (AF) Ablation Long-Term registry to analyze the usage of adenosine during PVI treatment in terms of rhythm outcome and safety. METHODS: The registry consists of 104 participating centers in 27 countries within the European Society of Cardiology. The registry data was split into an adenosine group (AG) and no-adenosine group (NAG). Procedure characteristics and patient outcome were compared. RESULTS: Adenosine was administered in 10.8% of the 3591 PVI patients included in the registry. Spain, the Netherlands, and Italy included the majority of adenosine cases (48.8%). Adenosine was applied more often in combination with open irrigation radiofrequency (RF) energy (74.7%) and less often in combination with nonirrigated RF energy (1.6%). After 1 year, a higher percentage of the AG was free from AF compared with the NAG (68.9% vs 59.1%, p < 0.001). Adenosine was associated with better rhythm outcome in RF ablation procedures, but not in cryo-ablation procedures (freedom from AF: RF: AG: 70.9%, NAG: 58.1%, p < 0.001, cryo: AG: 63.9%, NAG: 63.8%, p = 0.991). CONCLUSIONS: The use of adenosine was associated with a better rhythm outcome after 1 year follow-up and seems more useful in patients treated with RF energy compared with patients treated with cryo energy. Given the improved rhythm outcome at 1-year follow-up, it seems reasonable to encourage the use of adenosine during RF AF ablation.

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1235264784
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.1007.s10840-020-00744-8