Use of C-11-PE2I PET in Differential Diagnosis of Parkinsonian Disorders

Authors :
Appel, Lieuwe
Jonasson, My
Danfors, Torsten
Nyholm, Dag
Askmark, Håkan
Lubberink, Mark
Sörensen, Jens
Appel, Lieuwe
Jonasson, My
Danfors, Torsten
Nyholm, Dag
Askmark, Håkan
Lubberink, Mark
Sörensen, Jens
Publication Year :
2015

Abstract

In idiopathic Parkinson disease and atypical parkinsonian disorders, central dopaminergic and overall brain functional activity are altered to different degrees, causing difficulties in achieving an unambiguous clinical diagnosis. A dual examination using I-123-FP-CIT (I-123-N-omega-fluoropropyl- 2 beta-carbomethoxy-3 beta-(4-iodophenyl) nortropane, or I-123-ioflupane) SPECT and F-18-FDG PET provides complementary information on dopamine transporter (DAT) availability and overall brain functional activity, respectively. Parametric images based on a single, dynamic C-11-PE2I (N-(3-iodoprop-2E-enyl)-2 beta-carbomethoxy-3 beta-(4-methyl-phenyl) nortropane) scan potentially supply both DAT availability (nondisplaceable binding potential [BPND]) and relative cerebral blood flow (relative delivery [R-1]) at voxel level. This study aimed to evaluate the validity of C-11-PE2I PET against the dual-modality approach using I-123-FP-CIT SPECT and F-18-FDG PET. Methods: Sixteen patients with parkinsonian disorders had a dual examination with F-18-FDG PET and I-123-FP-CIT SPECT following clinical routines and additionally an experimental C-11-PE2I PET scan. Parametric BPND and R-1 images were generated using receptor parametric mapping with the cerebellum as a reference. T1-weighted MR imaging was used for automated definition of volumes of interest (VOI). The DAT VOIs included the basal ganglia, whereas the overall brain functional activity was examined using VOIs across the brain. BPND and R-1 values were compared with normalized I-123-FP-CIT and F-18-FDG uptake values, respectively, using Pearson correlations and regression analyses. In addition, 2 masked interpreters evaluated the images visually, in both the routine and the experimental datasets, for comparison of patient diagnoses. Results: Parametric C-11-PE2I BPND and R-1 images showed high consistency with I-123-FP-CIT SPECT and F-18-FDG PET images. Correlations between C-11-PE2I BPND and I-123-FP-CIT uptake ratios were

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1235168687
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.2967.jnumed.114.148619