Back to Search Start Over

Effect of the variability in implantation depth of intracorneal ring segments using the femtosecond laser technology in corneal ectasia

Authors :
Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Peris-Martínez, Cristina
Dualde-Beltrán, Cristina
Fernández-López, Ester
Roig-Revert, Maria José
Hernández-Díaz, Mikhail
Piñero, David P.
Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Peris-Martínez, Cristina
Dualde-Beltrán, Cristina
Fernández-López, Ester
Roig-Revert, Maria José
Hernández-Díaz, Mikhail
Piñero, David P.
Publication Year :
2020

Abstract

Purpose: To analyze the impact of the depth of implantation of intracorneal ring segments on morphological, biomechanical, and clinical outcomes in ectatic corneas. Methods: This prospective longitudinal study enrolled 40 eyes of 29 patients (age 20–51 years) with corneal ectasia that underwent intracorneal ring segments implantation (KeraRing, Mediphacos). Changes in visual acuity, refraction, corneal tomography, and corneal biomechanics (Ocular Response Analyzer, Reichert) were evaluated during a 6 month follow-up. Likewise, changes in ring segment implantation depth measured by optical coherence tomography (Visante OCT, Carl Zeiss Meditec) were also evaluated. Results: Mean relative depth of implantation was 71.6 ± 5.8%, 71.5 ± 6.5%, and 71.9 ± 6.3% at 1, 3, and 6 months after surgery, respectively (p = 0.827). The difference between the real relative depth of implantation and the theoretical attempted value of 70% was not statistically significant (p = 0.072). Differences in spherical equivalent during the follow-up changed significantly depending on the level of relative depth of implantation (p = 0.036), with an increase of 0.114 D per each 1% increase in relative depth of implantation. Likewise, a decrease of –0.194 D in the steepest keratometric reading was found per each decrease of 1% in relative depth of implantation (p = 0.026). Changes in corneal thickness (p = 0.092) and biomechanics (p = 0.080) were not related to relative depth of implantation. Conclusion: The effect on visual acuity and refraction of intracorneal ring segments when implanted in corneal ectasia is less clinically relevant when the implantation is done at a very deep plane. The variability of the depth of intracorneal ring segments implantation when using femtosecond laser technology is minimal and with no clinically significant effect on clinical outcomes.

Details

Database :
OAIster
Publication Type :
Electronic Resource
Accession number :
edsoai.on1176457058
Document Type :
Electronic Resource