New Position Algorithms for the 3-D CZT Drift Detector

Authors :
Budtz-Jørgensen, Carl
Kuvvetli, Irfan
Budtz-Jørgensen, Carl
Kuvvetli, Irfan
Source :
Budtz-Jørgensen , C & Kuvvetli , I 2017 , ' New Position Algorithms for the 3-D CZT Drift Detector ' , IEEE Transactions on Nuclear Science , vol. 64 , no. 6 , pp. 1611-1618 .
Publication Year :
2017

Abstract

The 3-D position sensitive CZT detector for high-energy astrophysics developed at DTU has been investigated with a digitizer readout system. The 3-D CZT detector is based on the CZT drift-strip detector principle and was fabricated using a REDLEN CZT crystal (20 mm x 20 mm x 5 mm). The detector contains 12 drift cells, each comprising one collecting anode strip with four drift strips, biased such that the electrons are focused and collected by the anode strips. Three-dimensional position determination is achieved using the anode strip signals, the drift-strip signals, and the signals from ten cathode strips. For the characterization work, we used a DAQ system with a 16 channels 250-MHz 14-b digitizer, SIS3316. It allowed us to analyze the pulse shapes of the signals from four detector cells at a time. The 3-D CZT setup was characterized with a finely collimated radioactive source of Cs-137 at 662 keV. The analysis required development of novel position determination algorithms which are the subject of this paper. Using the digitizer readout, we demonstrate improved position determination compared to the previous read out system based on analog electronics. Position resolutions of 0.4-mm full width at half maximum (FWHM) in the x-, y-, and z-directions were achieved and the energy resolution was 7.2-keV FWHM at 662 keV. The timing information allows identification of multiple interaction events within one detector cell, e.g., Compton scattering followed by photoelectric absorption. These characteristics are very important for a high-energy spectral-imager suitable for use in advanced Compton telescopes, or as focal detector for new hard X-ray and soft gamma-ray focusing telescopes or in polarimeter instrumentation. CZT detectors are attractive for these applications since they offer relatively high-quantum efficiency. From a technical point of view it is advantageous that their cooling requirements are modest.

Details

Database :
OAIster
Journal :
Budtz-Jørgensen , C & Kuvvetli , I 2017 , ' New Position Algorithms for the 3-D CZT Drift Detector ' , IEEE Transactions on Nuclear Science , vol. 64 , no. 6 , pp. 1611-1618 .
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1137571099
Document Type :
Electronic Resource