Back to Search
Start Over
Tribological Behaviour of Orthopaedic Ti-13Nb-13Zr and Ti-6Al-4V Alloys
- Source :
- Tribology Letters
- Publication Year :
- 2010
-
Abstract
- The aim of this study is to compare the tribological behaviour of novel orthopaedic implant alloy Ti-13Nb-13Zr with that of the standard Ti-6Al-4V ELI alloy, available in four different microstructural conditions produced by variations in the heat treatments. The friction and wear tests were performed by using a block-on-disc tribometer in Ringers solution at ambient temperature with a normal load of 20-60 N and sliding speed of 0.26-1.0 m/s. It was found that variations in microstructures produced significant variations in the wear resistance of Ti-6Al-4V ELI alloy. The wear losses of materials solution treated (ST) above the beta transus temperature are significantly lower compared with those of materials ST in the (alpha + beta) phase field and are almost insensitive to applied load and sliding speed. Wear loss of the (alpha + beta) ST Ti-6Al-4V ELI alloy continuously increased as applied load was increased and was highest at the highest sliding speed. The Ti-6Al-4V ELI alloy in all microstructural conditions possesses a much better wear resistance than cold-rolled Ti-13Nb-13Zr alloy. Friction results and morphology of worn surfaces showed that the observed behaviour is attributed to the predominant wear damage mechanism.
Details
- Database :
- OAIster
- Journal :
- Tribology Letters
- Notes :
- Tribology Letters
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1085022196
- Document Type :
- Electronic Resource