Back to Search Start Over

An Experimental study on effective depressurization actions for PWR vessel bottom small break LOCA with HPI failure and gas inflow, ROSA-V test SB-PV-04

Authors :
鈴木 光弘
Suzuki, Mitsuhiro
竹田 武司
Takeda, Takeshi
浅香 英明
Asaka, Hideaki
中村 秀夫
Nakamura, Hideo
鈴木 光弘
Suzuki, Mitsuhiro
竹田 武司
Takeda, Takeshi
浅香 英明
Asaka, Hideaki
中村 秀夫
Nakamura, Hideo
Publication Year :
2006

Abstract

A small break loss-of-coolant accident (SBLOCA) experiment was conducted at the Large Scale Test Facility of ROSA-V program to study effects of accident management (AM) measures on core cooling, which are important in case of total failure of high pressure injection system during an SBLOCA at a pressurized water reactor (PWR). The experiment (SB-PV-04) simulating a PWR vessel bottom SBLOCA with a rupture of ten instrument-tubes clarified that rapid depressurization action by full-opening of relief valves and supplying auxiliary feedwater were effective to avoid core uncovery through actuation of low pressure injection system irrespective of significantly degraded depressurization by non-condensable gas inflow from the accumulator tanks. It is clarified that the effective core cooling was established by the rapid primary cooling which contributed to preserve larger primary coolant mass than in the previous experiment (SB-PV-03) which was conducted with smaller primary cooling rate of -55 K/h as another AM action and resulted in core heatup.<br />A small break loss-of-coolant accident (SBLOCA) experiment was conducted at the Large Scale Test Facility of ROSA-V program to study effects of accident management (AM) measures on core cooling, which are important in case of total failure of high pressure injection system during an SBLOCA at a pressurized water reactor (PWR). The experiment (SB-PV-04) simulating a PWR vessel bottom SBLOCA with a rupture of ten instrument-tubes clarified that rapid depressurization action by full-opening of relief valves and supplying auxiliary feedwater were effective to avoid core uncovery through actuation of low pressure injection system irrespective of significantly degraded depressurization by non-condensable gas inflow from the accumulator tanks. It is clarified that the effective core cooling was established by the rapid primary cooling which contributed to preserve larger primary coolant mass than in the previous experiment (SB-PV-03) which was conducted with smaller primary cooling rate of -55 K/h as another AM action and resulted in core heatup.<br />著者所属: 日本原子力研究開発機構(JAEA)<br />JAEA-Research 2006-018

Details

Database :
OAIster
Notes :
English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1032397322
Document Type :
Electronic Resource