Back to Search Start Over

Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms

Authors :
Schaap, M. (Michiel)
Metz, C.T. (Coert)
Walsum, T.W. (Theo) van
Giessen, A.G. (Alina) van der
Weustink, A.C. (Annick)
Mollet, N.R.A. (Nico)
Bauer, C. (Christian)
Bogunović, H. (Hrvoje)
Castro, C. (Carlos)
Deng, X. (Xiang)
Dikici, E. (Engin)
O'Donnell, T. (Thomas)
Frenay, M. (Michel)
Friman, O. (Ola)
Hoyos, M.H.
Kitslaar, P.H. (Pieter)
Krissian, K. (Karl)
Kühnel, C. (Caroline)
Luengo-Oroz, M.A. (Miguel)
Orkisz, M. (Maciej)
Smedby, O.
Styner, M. (Martin)
Szymczak, A. (Andrzej)
Tek, H. (Hüseyin)
Wang, C. (Chunliang)
Warfield, S.K. (Simon)
Zambal, S. (Sebastian)
Zhang, Y. (Yong)
Krestin, G.P. (Gabriel)
Niessen, W.J. (Wiro)
Schaap, M. (Michiel)
Metz, C.T. (Coert)
Walsum, T.W. (Theo) van
Giessen, A.G. (Alina) van der
Weustink, A.C. (Annick)
Mollet, N.R.A. (Nico)
Bauer, C. (Christian)
Bogunović, H. (Hrvoje)
Castro, C. (Carlos)
Deng, X. (Xiang)
Dikici, E. (Engin)
O'Donnell, T. (Thomas)
Frenay, M. (Michel)
Friman, O. (Ola)
Hoyos, M.H.
Kitslaar, P.H. (Pieter)
Krissian, K. (Karl)
Kühnel, C. (Caroline)
Luengo-Oroz, M.A. (Miguel)
Orkisz, M. (Maciej)
Smedby, O.
Styner, M. (Martin)
Szymczak, A. (Andrzej)
Tek, H. (Hüseyin)
Wang, C. (Chunliang)
Warfield, S.K. (Simon)
Zambal, S. (Sebastian)
Zhang, Y. (Yong)
Krestin, G.P. (Gabriel)
Niessen, W.J. (Wiro)
Publication Year :
2009

Abstract

Efficiently obtaining a reliable coronary artery centerline from computed tomography angiography data is relevant in clinical practice. Whereas numerous methods have been presented for this purpose, up to now no standardized evaluation methodology has been published to reliably evaluate and compare the performance of the existing or newly developed coronary artery centerline extraction algorithms. This paper describes a standardized evaluation methodology and reference database for the quantitative evaluation of coronary artery centerline extraction algorithms. The contribution of this work is fourfold: (1) a method is described to create a consensus centerline with multiple observers, (2) well-defined measures are presented for the evaluation of coronary artery centerline extraction algorithms, (3) a database containing 32 cardiac CTA datasets with corresponding reference standard is described and made available, and (4) 13 coronary artery centerline extraction alg

Details

Database :
OAIster
Notes :
Medical Image Analysis vol. 13 no. 5, pp. 701-714, English
Publication Type :
Electronic Resource
Accession number :
edsoai.ocn957101697
Document Type :
Electronic Resource
Full Text :