Back to Search Start Over

Comparison of 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine-enhanced MRI in 471 patients with known or suspected renal lesions: Results of a multicenter, single-blind, interindividual, randomized clinical phase III trial

Authors :
Tombach, B. (Bernd)
Bohndorf, K. (Klaus)
Brodtrager, W. (Wolfgang)
Claussen, C.D. (Claus)
Düber, C. (Christoph)
Galanski, M. (Michael)
Grabbe, E. (Eckhardt)
Gortenuti, G. (Giacomo)
Kuhn, M. (Michael)
Gross-Fengels, W. (Walter)
Hammerstingl, R. (Renate)
Happel, B. (Brigitte)
Heinz-Peer, G. (Gertraud)
Jung, G. (Gregor)
Kittner, T. (Thomas)
Lagalla, R.
Lengsfeld, P. (Philipp)
Loose, R. (Reinhard)
Oyen, R.H.G. (Raymond)
Pavlica, P. (Pietro)
Pering, C. (Christiane)
Pozzi Mucelli, R. (Roberto Silvio)
Persigehl, T. (Thorsten)
Reimer, P. (Peter)
Renken, N.S. (Nomdo)
Richter, G.M. (Götz)
Rummeny, E.J. (Ernst)
Schäfer, F. (Fritz)
Szczerbo-Trojanowska, M. (Malgorzata)
Urbanik, A. (Andrzej)
Vogl, T.J. (Thomas)
Hajek, P. (Paul)
Tombach, B. (Bernd)
Bohndorf, K. (Klaus)
Brodtrager, W. (Wolfgang)
Claussen, C.D. (Claus)
Düber, C. (Christoph)
Galanski, M. (Michael)
Grabbe, E. (Eckhardt)
Gortenuti, G. (Giacomo)
Kuhn, M. (Michael)
Gross-Fengels, W. (Walter)
Hammerstingl, R. (Renate)
Happel, B. (Brigitte)
Heinz-Peer, G. (Gertraud)
Jung, G. (Gregor)
Kittner, T. (Thomas)
Lagalla, R.
Lengsfeld, P. (Philipp)
Loose, R. (Reinhard)
Oyen, R.H.G. (Raymond)
Pavlica, P. (Pietro)
Pering, C. (Christiane)
Pozzi Mucelli, R. (Roberto Silvio)
Persigehl, T. (Thorsten)
Reimer, P. (Peter)
Renken, N.S. (Nomdo)
Richter, G.M. (Götz)
Rummeny, E.J. (Ernst)
Schäfer, F. (Fritz)
Szczerbo-Trojanowska, M. (Malgorzata)
Urbanik, A. (Andrzej)
Vogl, T.J. (Thomas)
Hajek, P. (Paul)
Publication Year :
2008

Abstract

The purpose of this phase III clinical trial was to compare two different extracellular contrast agents, 1.0 M gadobutrol and 0.5 M gadopentate dimeglumine, for magnetic resonance imaging (MRI) in patients with known or suspected focal renal lesions. Using a multicenter, single-blind, interindividual, randomized study design, both contrast agents were compared in a total of 471 patients regarding their diagnostic accuracy, sensitivity, and specificity to correctly classify focal lesions of the kidney. To test for noninferiority the diagnostic accuracy rates for both contrast agents were compared with CT results based on a blinded reading. The average diagnostic accuracy across the three blinded readers ('average reader') was 83.7% for gadobutrol and 87.3% for gadopentate dimeglumine. The increase in accuracy from precontrast to combined precontrast and postcontrast MRI was 8.0% for gadobutrol and 6.9% for gadopentate dimeglumine. Sensitivity of the average reader was 85.2% for gadobutrol and 88.7% for gadopentate dimeglumine. Specificity of the average reader was 82.1% for gadobutrol and 86.1% for gadopentate dimeglumine. In conclusion, this study documents evidence for the noninferiority of a single i.v. bolus injection of 1.0 M gadobutrol compared with 0.5 M gadopentate dimeglumine in the diagnostic assessment of renal lesions with CE-MRI.

Details

Database :
OAIster
Notes :
application/pdf, European Radiology: journal of the European Congress of Radiology vol. 18 no. 11, pp. 2610-2619, English
Publication Type :
Electronic Resource
Accession number :
edsoai.ocn957098974
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.1007.s00330-008-1054-2