Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction : Two-year clinical results of the COMFORTABLE AMI trial

Authors :
Räber, Lorenz
Kelbæk, Henning
Taniwaki, Masanori
Ostojic, Miodrag
Heg, Dik
Baumbach, Andreas
von Birgelen, Clemens
Roffi, Marco
Tüller, David
Engstrøm, Thomas
Moschovitis, Aris
Pedrazzini, Giovanni
Wenaweser, Peter
Kornowski, Ran
Weber, Klaus
Lüscher, Thomas F
Matter, Christian M
Meier, Bernhard
Jüni, Peter
Windecker, Stephan
Räber, Lorenz
Kelbæk, Henning
Taniwaki, Masanori
Ostojic, Miodrag
Heg, Dik
Baumbach, Andreas
von Birgelen, Clemens
Roffi, Marco
Tüller, David
Engstrøm, Thomas
Moschovitis, Aris
Pedrazzini, Giovanni
Wenaweser, Peter
Kornowski, Ran
Weber, Klaus
Lüscher, Thomas F
Matter, Christian M
Meier, Bernhard
Jüni, Peter
Windecker, Stephan
Source :
Räber, Lorenz; Kelbæk, Henning; Taniwaki, Masanori; Ostojic, Miodrag; Heg, Dik; Baumbach, Andreas; von Birgelen, Clemens; Roffi, Marco; Tüller, David; Engstrøm, Thomas; Moschovitis, Aris; Pedrazzini, Giovanni; Wenaweser, Peter; Kornowski, Ran; Weber, Klaus; Lüscher, Thomas F; Matter, Christian M; Meier, Bernhard; Jüni, Peter; Windecker, Stephan (2014). Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction : Two-year clinical results of the COMFORTABLE AMI trial. Circulation. Cardiovascular Interventions, 7(3):355-364.
Publication Year :
2014

Abstract

BACKGROUND: This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) were sustained during long-term follow-up. METHODS AND RESULTS: A total of 1161 patients were randomly assigned to biolimus-eluting stent (BES) and BMS at 11 centers, and follow-up rates at 2 years were 96.3%. A subgroup of 103 patients underwent angiography at 13 months. At 2 years, differences in the primary end point of cardiac death, target-vessel myocardial infarction, and target lesion revascularization continued to diverge in favor of BES-treated patients (5.8%) compared with BMS-treated patients (11.9%; hazard ratio = 0.48; 95% confidence interval, 0.31-0.72; P < 0.001) with a significant risk reduction during the second year of follow-up (hazard ratio 1-2 years = 0.45; 95% confidence interval, 0.20-1.00; P = 0.049). Differences in the primary end point were driven by a reduction in target lesion revascularization (3.1% versus 8.2%; P < 0.001) and target-vessel reinfarction (1.3% versus 3.4%; P = 0.023). The composite of death, any reinfarction and revascularization (14.5% versus 19.3%; P = 0.03), and cardiac death or target-vessel myocardial infarction (4.2% versus 7.2%; P = 0.036) were less frequent among BES-treated patients compared with BMS-treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0 ± 7.2 in BES- and 39.6 ± 25.2 in BMS-treated lesions (P < 0.001). CONCLUSIONS: Among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued to improve cardiovascular events compared with BMS beyond 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NTC00962416.

Details

Database :
OAIster
Journal :
Räber, Lorenz; Kelbæk, Henning; Taniwaki, Masanori; Ostojic, Miodrag; Heg, Dik; Baumbach, Andreas; von Birgelen, Clemens; Roffi, Marco; Tüller, David; Engstrøm, Thomas; Moschovitis, Aris; Pedrazzini, Giovanni; Wenaweser, Peter; Kornowski, Ran; Weber, Klaus; Lüscher, Thomas F; Matter, Christian M; Meier, Bernhard; Jüni, Peter; Windecker, Stephan (2014). Biolimus-eluting stents with biodegradable polymer versus bare-metal stents in acute myocardial infarction : Two-year clinical results of the COMFORTABLE AMI trial. Circulation. Cardiovascular Interventions, 7(3):355-364.
Notes :
application/pdf, info:doi/10.5167/uzh-105993, English
Publication Type :
Electronic Resource
Accession number :
edsoai.ocn942503024
Document Type :
Electronic Resource