Abstract
- After five years of operation, LANDSAT 3 retired from the operation in March 1983. Onboard two RBV (Return Beam Vidicon Camera) of this satellite had non-uniform sensitivity called shading on the photo-electric plane, so that the LANDSAT ground stations in the world, which had only correction coefficient before the launch of the satellite, experienced a lot of difficulty in correcting the data. The Earth Observation Center periodically gathered the correction ramp data every 10 days and modified the correction coefficients based on these data, in order to reprocess the data. The correction of ramp data is only means for the quantitative evaluation of the sensitivity characteristics of RBV in the space environment. The analyses of these data will contribute to the development of the sensor correction system and the data processing algorithm on the ground.<br />ランドサット3号は5年間の運用の後1983年3月に引退した。同衛星に搭載された2台のRBV(リターン・ビーム・ビジコン・カメラ)はシェーディングと呼ばれる光電面の感度の不均一性を持っており、打ち上げ前の補正係数しか持っていない世界中のランドサット地上局はその補正に苦労した。地球観測センターはランドサット地上局の中で唯一、校正ランプデータを10日毎に定期的に受信し、そのデータを基に補正係数を更新し補正処理を行った。校正ランプデータは宇宙環境におけるRBVの感度特性を定量的に評価できる唯一の手段であり、その解析結果は今後のセンサー校正システム及び地上処理アルゴリズムの開発の参考となる。