Intermediate follow-up following intravascular stenting for treatment of coarctation of the aorta

Authors :
Children's Hospital of Michigan, Wayne State University, Detroit, Michigan ; Children's Hospital of Michigan, 3901 Beaubien Blvd, Detroit, MI 48201
University of California at San Francisco, Division of Cardiology, San Francisco, California
Instituto Dante Pazzanese de Cardiologia, Sao Paulo, SP, Brazil
The Congenital Heart Institute at Miami, Children's Hospital and Arnold Palmer Women and Children's Hospital, Orlando, Florida
Children's Hospital of Omaha, University of Nebraska Creighton University, Omaha, Nebraska
Children's Hospital of Michigan, Wayne State University, Detroit, Michigan
Guy's Hospital, London, England
Columbus Children's Hospital, Ohio State University, Columbus, Ohio
Children's Hospital of Mississippi, University of Mississippi/Jackson, Mississipi
University of Chicago, Division of Cardiology, Chicago, Illinois
Mayo Clinic, Rochester, Minnesota
Cardiovascular Center Bethanien, Frankfurt, Germany
Children's Hospital of Iowa, University of Iowa, Iowa City, Iowa
Medical University of South Carolina, Division of Cardiology, Charleston, South Carolina
Children's Memorial Hospital, Northwestern University, Lincoln Park, Illinois
Duke Children's Heart Program, Duke University, Durham, North Carolina
Seattle Children's Hospital, University of Washington, Seattle, Washington
Babies and Children's Hospital of New York, Columbia Presbyterian, New York, New York
Forbes, Thomas J.
Moore, Phillip
Pedra, Carlos A. C.
Zahn, Evan M.
Nykanen, David
Amin, Zahid
Garekar, Swati
Teitel, David
Qureshi, Shakeel A.
Cheatham, John P.
Ebeid, Makram R.
Hijazi, Ziyad M.
Sandhu, Satinder
Hagler, Donald J.
Sievert, Horst
Fagan, Thomas E.
Ringwald, Jeremy
Du, Wei
Tang, Liwen
Wax, David F.
Rhodes, John
Johnston, Troy A.
Jones, Thomas K.
Turner, Daniel R.
Pass, Robert
Torres, Alejandro
Hellenbrand, William E.
Children's Hospital of Michigan, Wayne State University, Detroit, Michigan ; Children's Hospital of Michigan, 3901 Beaubien Blvd, Detroit, MI 48201
University of California at San Francisco, Division of Cardiology, San Francisco, California
Instituto Dante Pazzanese de Cardiologia, Sao Paulo, SP, Brazil
The Congenital Heart Institute at Miami, Children's Hospital and Arnold Palmer Women and Children's Hospital, Orlando, Florida
Children's Hospital of Omaha, University of Nebraska Creighton University, Omaha, Nebraska
Children's Hospital of Michigan, Wayne State University, Detroit, Michigan
Guy's Hospital, London, England
Columbus Children's Hospital, Ohio State University, Columbus, Ohio
Children's Hospital of Mississippi, University of Mississippi/Jackson, Mississipi
University of Chicago, Division of Cardiology, Chicago, Illinois
Mayo Clinic, Rochester, Minnesota
Cardiovascular Center Bethanien, Frankfurt, Germany
Children's Hospital of Iowa, University of Iowa, Iowa City, Iowa
Medical University of South Carolina, Division of Cardiology, Charleston, South Carolina
Children's Memorial Hospital, Northwestern University, Lincoln Park, Illinois
Duke Children's Heart Program, Duke University, Durham, North Carolina
Seattle Children's Hospital, University of Washington, Seattle, Washington
Babies and Children's Hospital of New York, Columbia Presbyterian, New York, New York
Forbes, Thomas J.
Moore, Phillip
Pedra, Carlos A. C.
Zahn, Evan M.
Nykanen, David
Amin, Zahid
Garekar, Swati
Teitel, David
Qureshi, Shakeel A.
Cheatham, John P.
Ebeid, Makram R.
Hijazi, Ziyad M.
Sandhu, Satinder
Hagler, Donald J.
Sievert, Horst
Fagan, Thomas E.
Ringwald, Jeremy
Du, Wei
Tang, Liwen
Wax, David F.
Rhodes, John
Johnston, Troy A.
Jones, Thomas K.
Turner, Daniel R.
Pass, Robert
Torres, Alejandro
Hellenbrand, William E.
Publication Year :
2007

Abstract

Background : We report a multiinstitutional study on intermediate-term outcome of intravascular stenting for treatment of coarctation of the aorta using integrated arch imaging (IAI) techniques. Methods and Results : Medical records of 578 patients from 17 institutions were reviewed. A total of 588 procedures were performed between May 1989 and Aug 2005. About 27% (160/588) procedures were followed up by further IAI of their aorta (MRI/CT/repeat cardiac catheterization) after initial stent procedures. Abnormal imaging studies included: the presence of dissection or aneurysm formation, stent fracture, or the presence of reobstruction within the stent (instent restenosis or significant intimal build-up within the stent). Forty-one abnormal imaging studies were reported in the intermediate follow-up at median 12 months (0.5–92 months). Smaller postintervention of the aorta (CoA) diameter and an increased persistent systolic pressure gradient were associated with encountering abnormal follow-up imaging studies. Aortic wall abnormalities included dissections ( n = 5) and aneurysm ( n = 13). The risk of encountering aortic wall abnormalities increased with larger percent increase in CoA diameter poststent implant, increasing balloon/coarc ratio, and performing prestent angioplasty. Stent restenosis was observed in 5/6 parts encountering stent fracture and neointimal buildup ( n = 16). Small CoA diameter poststent implant and increased poststent residual pressure gradient increased the likelihood of encountering instent restenosis at intermediate follow-up. Conclusions : Abnormalities were observed at intermediate follow-up following IS placement for treatment of native and recurrent coarctation of the aorta. Not exceeding a balloon:coarctation ratio of 3.5 and avoidance of prestent angioplasty decreased the likelihood of encountering an abnormal follow-up imaging study in patients undergoing intravascular stent placement for the treatment of coarctation of the aorta. We r