Back to Search Start Over

RH1021BMH-10 Precision 10 V Reference Total Ionizing Dose Test Report

Authors :
Casey, Megan
Topper, Alyson
Phan, Anthony M
Publication Year :
2020
Publisher :
United States: NASA Center for Aerospace Information (CASI), 2020.

Abstract

The purpose of this test was to validate the Analog Devices (ADI) RH1021BMH-10 flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for this flight lot with wafer lot number 769658.1 and lot date code (LDC) 1430A. Low dose rate (LDR) irradiations were performed in this test so that the device susceptibility to enhanced low dose rate sensitivity (ELDRS) could be determined.

Details

Language :
English
Database :
NASA Technical Reports
Notes :
80GSFC18C0120
Publication Type :
Report
Accession number :
edsnas.20200001449
Document Type :
Report