Back to Search
Start Over
Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
- Publication Year :
- 2015
- Publisher :
- United States: NASA Center for Aerospace Information (CASI), 2015.
-
Abstract
- An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
- Subjects :
- Mechanical Engineering
Subjects
Details
- Language :
- English
- Database :
- NASA Technical Reports
- Notes :
- NNC13BA10B, , WBS 871056.06.02.01.09.02
- Publication Type :
- Report
- Accession number :
- edsnas.20150022419
- Document Type :
- Report