Back to Search Start Over

Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

Authors :
J P Sass
W W St Cyr
T M Barrett
R G Baumgartner
J W Lott
J E Fesmire
Source :
AIP Conference Proceedings. 1218(1)
Publication Year :
2010
Publisher :
United States: NASA Center for Aerospace Information (CASI), 2010.

Abstract

A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years.

Subjects

Subjects :
Propellants And Fuels

Details

Language :
English
ISBN :
978-0-7354-0761-9
ISSN :
15517616, 97807354, and 0094243X
ISBNs :
9780735407619
Volume :
1218
Issue :
1
Database :
NASA Technical Reports
Journal :
AIP Conference Proceedings
Publication Type :
Report
Accession number :
edsnas.20130011367
Document Type :
Report
Full Text :
https://doi.org/10.1063/1.3422430