Back to Search
Start Over
Processes to Open the Container and the Sample Catcher of the Hayabusa Returned Capsule in the Planetary Material Sample Curation Facility of JAXA
- Publication Year :
- 2011
- Publisher :
- United States: NASA Center for Aerospace Information (CASI), 2011.
-
Abstract
- Japanese spacecraft Hayabusa, which returned from near-Earth-asteroid Itokawa, successfully returned its reentry capsule to the Earth, the Woomera Prohibited Area in Australia in Jun 13th, 2010, as detailed in another paper [1]. The capsule introduced into the Planetary Material Sample Curation Facility in the Sagamihara campus of JAXA in the early morning of June 18th. Hereafter, we describe a series of processes for the returned capsule and the container to recover gas and materials in there. A transportation box of the recovered capsule was cleaned up on its outer surface beforehand and introduced into the class 10,000 clean room of the facility. Then, the capsule was extracted from the box and its plastic bag was opened and checked and photographed the outer surface of the capsule. The capsule was composed of the container, a backside ablator, a side ablator, an electronic box and a supporting frame. The container consists of an outer lid, an inner lid, a frame for latches, a container and a sample catcher, which is composed of room A and B and a rotational cylinder. After the first check, the capsule was packed in a plastic bag with N2 again, and transferred to the Chofu campus in JAXA, where the X-ray CT instrument is situated. The first X-ray CT analysis was performed on the whole returned capsule for confirming the conditions of latches and O-ring seal of the container. The analysis showed that the latches of the container should have worked normally, and that the double Orings of the container seemed to be sealed its sample catcher with no problem. After the first X-ray CT, the capsule was sent back to Sagamihara and introduced in the clean room to exclude the electronic box and the side ablator from the container by hand tools. Then the container with the backside ablator was set firmly to special jigs to fix the lid of container tightly to the container and set to a milling machine. The backside ablator was drilled by the machine to expose heads of bolts, which combined the ablator to the outer lid of the container, and after the drilling had been finished, all the bolts were unscrewed and the backside ablator was removed from the container. Then, the container was sent to the Chofu X-ray facility again to examine in detail by a micro X-ray CT instrument in order to reconfirm that the condition of the latches of the lid of container was normal and that its double O-ring seemed to have been sealed after the last X-ray CT analysis.
- Subjects :
- Space Sciences (General)
Subjects
Details
- Language :
- English
- Database :
- NASA Technical Reports
- Publication Type :
- Report
- Accession number :
- edsnas.20110005572
- Document Type :
- Report