Evaluation of hole sizes in structures requiring EVA services as a means to prevent gloved-hand finger entrapment
- Publication Year :
- 1993
- Publisher :
- United States: NASA Center for Aerospace Information (CASI), 1993.
-
Abstract
- One of the concerns of Space Station designers was making sure that the suited crewmembers' gloved fingers are not trapped in the holes that may be present in the structures during EVA activities. A study was conducted on 11 subjects to determine the minimum and maximum possible hole sizes that would eliminate the possibility of finger entrapment. Subjects wore pressurized gloves and attempted to insert their fingers into holes of various sizes. Based on the experimental results, it is recommended that the smallest diameter should be less than 13.0 mm and the largest diameter should be greater than 35.0 mm in order to eliminate the possibility of finger entrapment while wearing gloves. It is also recommended that the current requirements specified by the MSIS-STD-3000 (Section 6.3.3.4) should be modified accordingly.