Pulmonary tolerance in man to continuous oxygen exposure at 3.0, 2.5, 2.0, and 1.5 ATA in Predictive Studies V

Authors :
Clark, J. M
Gelfand, R
Flores, N. D
Lambertsen, C. J
Pisarello, J. B
Publication Year :
1987
Publisher :
United States: NASA Center for Aerospace Information (CASI), 1987.

Abstract

Oxygen effects on pulmonary function were measured in normal, resting men who breathed oxygen continuously at 3.0, 2.5, 2.0, and 1.5 ATA to predefined limits of CNS, cardiac, or pulmonary tolerance. Rates of pulmonary symptom intensification and decrease in vital capacity (VC) increased progressively with elevation of inspired oxygen pressure. Although VC decrements occurred concurrently with symptoms, the lung volume changes became prominent when symptoms were still mild. The observed effects were consistent with the interpretation that small airway function is impaired more selectively by oxygen exposure at 3.0 and 2.5 ATA than by exposure at 2.0 and 1.5 ATA. Despite similar VC changes after oxygen exposure at 2.0 ATA for nearly 10 hr and exposure at 1.5 ATA for almost 18 hr, the 2.0 ATA exposure caused greater impairment of pulmonary function and required a longer recovery period.

Subjects

Subjects :
Aerospace Medicine

Details

Language :
English
Database :
NASA Technical Reports
Notes :
N00014-81-C-0826, , NAS9-17238
Publication Type :
Report
Accession number :
edsnas.19890066327
Document Type :