Abstract

Calculations have predicted the existence of crystallographically doubly rotated quartz orientations with turnover temperatures which are considerably less sensitive to angular misorientation then comparable AT- or BT-cuts. These crystals are arbitrarily designated as the AK-cut. Experimental data is given for seven orientations, phi-angle variations between 30-46 deg and theta-angle variations between 21-28 deg measured on 3.3-3.4 MHz fundamental mode resonators vibrating in the thickness shear c-mode. The experimental turnover temperatures of these resonators are between 80 C and 150 C, in general agreement with calculated values. The normalized frequency change as a function of temperature has been fitted with a cubic equation.