Back to Search
Start Over
Comparison of computer-acquired performance data from several fixed spaced planar diodes.
- Publication Year :
- 1971
- Publisher :
- United States: NASA Center for Aerospace Information (CASI), 1971.
-
Abstract
- Performance data are compared for thermionic diodes with various tungsten or rhenium emitters and niobium or molybdenum collectors. The planar converters have guard-ringed collectors and a fixed space of 10 mils (0.254 mm). The data were acquired using a computer. The parameters are the temperatures of the emitter Te, collector Tc, and cesium reservoir Tr. The composite plots have constant Te and varying Tc or Tr or both. The envelope and composite plots having constant Te are presented. The diodes were tested at increments between 1500 and 2000 K for the emitters, 750 and 1100 K for the collectors, and 520 and 650 K for the reservoirs.