Back to Search
Start Over
Coronary MR angiography at 3T: fat suppression versus water-fat separation
- Source :
- Nezafat, Maryam, Markus Henningsson, David P. Ripley, Nathalie Dedieu, Gerald Greil, John P. Greenwood, Peter Börnert, Sven Plein, and René M. Botnar. 2016. “Coronary MR angiography at 3T: fat suppression versus water-fat separation.” Magma (New York, N.y.) 29 (5): 733-738. doi:10.1007/s10334-016-0550-7. http://dx.doi.org/10.1007/s10334-016-0550-7.
- Publication Year :
- 2016
- Publisher :
- Springer Berlin Heidelberg, 2016.
-
Abstract
- Objectives: To compare Dixon water-fat suppression with spectral pre-saturation with inversion recovery (SPIR) at 3T for coronary magnetic resonance angiography (MRA) and to demonstrate the feasibility of fat suppressed coronary MRA at 3T without administration of a contrast agent. Materials and methods Coronary MRA with Dixon water-fat separation or with SPIR fat suppression was compared on a 3T scanner equipped with a 32-channel cardiac receiver coil. Eight healthy volunteers were examined. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), right coronary artery (RCA), and left anterior descending (LAD) coronary artery sharpness and length were measured and statistically compared. Two experienced cardiologists graded the visual image quality of reformatted Dixon and SPIR images (1: poor quality to 5: excellent quality). Results: Coronary MRA images in healthy volunteers showed improved contrast with the Dixon technique compared to SPIR (CNR blood-fat: Dixon = 14.9 ± 2.9 and SPIR = 13.9 ± 2.1; p = 0.08, CNR blood-myocardium: Dixon = 10.2 ± 2.7 and SPIR = 9.11 ± 2.6; p = 0.1). The Dixon method led to similar fat suppression (fat SNR with Dixon: 2.1 ± 0.5 vs. SPIR: 2.4 ± 1.2, p = 0.3), but resulted in significantly increased SNR of blood (blood SNR with Dixon: 19.9 ± 4.5 vs. SPIR: 15.5 ± 3.1, p < 0.05). This means the residual fat signal is slightly lower with the Dixon compared to the SIPR technique (although not significant), while the SNR of blood is significantly higher with the Dixon technique. Vessel sharpness of the RCA was similar for Dixon and SPIR (57 ± 7 % vs. 56 ± 9 %, p = 0.2), while the RCA visualized vessel length was increased compared to SPIR fat suppression (107 ± 21 vs. 101 ± 21 mm, p < 0.001). For the LAD, vessel sharpness (50 ± 13 % vs. 50 ± 7 %, p = 0.4) and vessel length (92 ± 46 vs. 90 ± 47 mm, p = 0.4) were similar with both techniques. Consequently, the Dixon technique resulted in an improved visual score of the coronary arteries in the water fat separated images of healthy subjects (RCA: 4.6 ± 0.5 vs. 4.1 ± 0.7, p = 0.01, LAD: 4.1 ± 0.7 vs. 3.5 ± 0.8, p = 0.007). Conclusions: Dixon water-fat separation can significantly improve coronary artery image quality without the use of a contrast agent at 3T.
- Subjects :
- Coronary magnetic resonance angiography
SPIR
Dixon
Vessel length
Vessel sharpness
Subjects
Details
- Language :
- English
- ISSN :
- 09685243
- Database :
- Digital Access to Scholarship at Harvard (DASH)
- Journal :
- Nezafat, Maryam, Markus Henningsson, David P. Ripley, Nathalie Dedieu, Gerald Greil, John P. Greenwood, Peter Börnert, Sven Plein, and René M. Botnar. 2016. “Coronary MR angiography at 3T: fat suppression versus water-fat separation.” Magma (New York, N.y.) 29 (5): 733-738. doi:10.1007/s10334-016-0550-7. http://dx.doi.org/10.1007/s10334-016-0550-7.
- Publication Type :
- Academic Journal
- Accession number :
- edshld.1.29408185
- Document Type :
- Journal Article
- Full Text :
- https://doi.org/10.1007/s10334-016-0550-7