Back to Search Start Over

The safety and feasibility of three-dimensional visualization planning system for CT-guided microwave ablation of stage I NSCLC (diameter ≤2.5 cm): A pilot study

Authors :
Hu, Yanting
Xue, Guoliang
Liang, Xinyu
Wu, Jing
Zhang, Peng
Wang, Nan
Li, Zhichao
Cao, Pikun
Wang, Gang
Cai, Hongchao
Wei, Zhigang
Ye, Xin
Source :
Journal of Cancer Research and Therapeutics. March 1, 2023, Vol. 19 Issue 1, p64, 7 p.
Publication Year :
2023

Abstract

ABSTRACT Background: Microwave ablation (MWA) of lung tumors is a technique that is dependent on the ablationist's level of expertise. The selection of the optimum puncture path and determination of appropriate ablative parameters is the key to the success and safe of the procedure. The objective of this study was to describe the clinical use of a novel three-dimensional visualization ablation planning system (3D-VAPS) for aided MWA of stage I non-small cell lung cancer (NSCLC). Methods: This was a single-arm, single-center, retrospective study. From May 2020 to July 2022, 113 consented patients with stage I NSCLC received MWA treatment in 120 MWA sessions. The 3D-VAPS was used to determine that (1) the overlap between the gross tumor region and simulated ablation; (2) the proper posture and appropriate puncture site on the surface of the body; (3) the puncture path; and (4) presetting preliminarily ablative parameters. Patients were monitored with contrast-enhanced CT scans at 1, 3, and 6 months, as well as every 6 months following that. The primary endpoints were technical success and a complete ablation rate. Local progression-free survival (LPFS), overall survival (OS), and comorbidities were secondary study objectives. Results: The mean diameter of tumors was 1.9 ± 0.4 cm (range 0.9-2.5 cm). The mean duration was 5.34 ± 1.28 min (range 3.0-10.0 min). The mean power output was 42.58 ± 4.23 (range 30.0-50.0W). The median follow-up time was 19.0 months (6.0-26.0 months). The technical success rate was 100. Three-month after the procedure, the complete ablation rate was 97.35. 6, 9, 12, and 24 months LPFS rates were 100, 98.23, 98.23, and 96.46, respectively. One-year and 2-year OS rates were 100 and 100. There were no patients who died both during the procedure and after the MWA of 30 days. The complications after MWA included pneumothorax (38.33), pleural effusion (26.67), intrapulmonary hemorrhage (31.67), and pulmonary infection (2.50). Conclusions: This research describes and confirms that 3D-VAPS is a feasibility and safe method for MWA of stage I NSCLC treatment. 3D-VAPS may be helpful to optimize the puncture path, assess reasonable ablative parameters, and minimize complications. Keywords: Microwave ablation, non-small cell lung cancer, three-dimensional visualization planning system<br />Author(s): Yanting Hu [1]; Guoliang Xue [1]; Xinyu Liang [1,2]; Jing Wu [3]; Peng Zhang [4]; Nan Wang [1]; Zhichao Li [1]; Pikun Cao [1]; Gang Wang [1]; Hongchao Cai [...]

Details

Language :
English
ISSN :
09731482
Volume :
19
Issue :
1
Database :
Gale General OneFile
Journal :
Journal of Cancer Research and Therapeutics
Publication Type :
Periodical
Accession number :
edsgcl.818205835
Full Text :
https://doi.org/10.4103/jcrt.jcrt_2093_22