Back to Search Start Over

The Percentage of [-2]Pro-Prostate-Specific Antigen and the Prostate Health Index Outperform Prostate-Specific Antigen and the Percentage of Free Prostate-Specific Antigen in the Detection of Clinically Significant Prostate Cancer and Can Be Used as Reflex Tests

Authors :
Garrido, Manuel M.
Marta, Jose C.
Bernardino, Rui M.
Guerra, Joao
Fernandes, Francisco
Pereira, Maria H.
Ribeiro, Ruy
Holdenrieder, Stefan
Pinheiro, Luis C.
Guimaraes, Joao T.
Source :
Archives of Pathology & Laboratory Medicine. June, 2022, Vol. 146 Issue 6, p691, 10 p.
Publication Year :
2022

Abstract

* Context.--There is a need to avoid the overdiagnosis of prostate cancer (PCa) and to find more specific biomarkers. Objective.--To evaluate the clinical utility of [-2]proprostate-specific antigen ([-2]proPSA) derivatives in detecting clinically significant PCa (csPCa) and to compare it with prostate-specific antigen (PSA) and with the percentage of free PSA (%fPSA). Design.--Two hundred thirty-seven men (PSA: 2-10 ng/ mL) scheduled for a prostate biopsy were enrolled. Parametric and nonparametric tests, receiver operating characteristic curves, and logistic regression analysis were applied. Outcomes were csPCa and overall PCa. Results.--Both [-2]proPSA derivatives were significantly higher in csPCa and overall PCa (P < .001). The areas under the curves for the prediction of csPCa were higher for the percentage of [-2]proPSA (%[-2]proPSA) (0.781) and the prostate health index (PHI) (0.814) than for PSA (0.651) and %fPSA (0.724). There was a gain of 11% in diagnostic accuracy when %[-2]proPSA or PHI were added to a base model with PSA and %fPSA. Twenty-five percent to 29% of biopsies could have been spared with %[-2]proPSA (cutoff: [greater than or equal to] 1.25%) and PHI (cutoff: [greater than or equal to] 27), missing 10% of csPCas. The same results could have been achieved by using [-2]proPSA as a reflex test, when %fPSA was 25% or less (cutoffs: [greater than or equal to] 1.12% and [greater than or equal to] 24 for %[-2]proPSA and PHI, respectively). Conclusions.--The [-2]proPSA derivatives improve the diagnostic accuracy of csPCa when the PSA value is between 2 and 10 ng/mL, sparing unnecessary biopsies and selecting patients for active surveillance. [-2]proPSA can be used as a reflex test when %fPSA is 25% or less, without reducing the diagnostic accuracy for csPCa and the number of spared biopsies.<br />Prostate cancer (PCa) is estimated to be the malignancy with the highest incidence in men in 2020, both in the United States and in Europe, (1,2) being the second leading [...]

Details

Language :
English
ISSN :
15432165
Volume :
146
Issue :
6
Database :
Gale General OneFile
Journal :
Archives of Pathology & Laboratory Medicine
Publication Type :
Academic Journal
Accession number :
edsgcl.705931984
Full Text :
https://doi.org/10.5858/arpa.2021-0079-OA