Back to Search Start Over

Diagnostic Accuracy of the AzBio Speech Recognition in Noise Test

Authors :
Vermiglio, Andrew J.
Leclerc, Lauren
Thornton, Meagan
Osborne, Hannah
Bonilla, Elizabeth
Fang, Xiangming
Source :
Journal of Speech, Language, and Hearing Research. August, 2021, Vol. 64 Issue 8, p3303, 14 p.
Publication Year :
2021

Abstract

Purpose: The goal of this study was to determine the ability of the AzBio speech recognition in noise (SRN) test to distinguish between groups of participants with and without a self-reported SRN disorder and a self-reported signal-tonoise ratio (SNR) loss. Method: Fifty-four native English-speaking young adults with normal pure-tone thresholds (< 25 dB HL, 0.25-6.0 kHz) participated. Individuals who reported hearing difficulty in a noisy restaurant (Reference Standard 1) were placed in the SRN disorder group. SNR loss groups were created based on the self-report of the ability to hear Hearing in Noise Test (HINT) sentences in steady-state speech-shaped noise, four-talker babble, and 20-talker babble in a controlled listening environment (Reference Standard 2). Participants with HINT thresholds poorer than or equal to the median were assigned to the SNR loss group. Results: The area under the curve from the receiver operating characteristics curves revealed that the AzBio test was not a significant predictor of an SRN disorder, or an SNR loss using the steady-state noise Reference Standard 2 condition. However, the AzBio was a significant predictor of an SNR loss using the four-talker babble and 20-talker babble Reference Standard 2 conditions (p < .05). The AzBio was a significant predictor of an SNR loss when using the average HINT thresholds across the three Reference Standard 2 masker conditions (area under the curve = .79, p = .001). Conclusions: The AzBio test was not a significant predictor of a self-reported SRN disorder or a self-reported SNR loss in steady-state noise. However, it was a significant predictor of a self-reported SNR loss in babble noise and the average across all noise conditions. A battery of reference standard tests with a range of maskers in a controlled listening environment is recommended for diagnostic accuracy evaluations of SRN tests.<br />According to the American Academy of Otolaryngology and American Council of Otolaryngology (AAO-ACO), pure-tone threshold testing was considered a tentative best measure of hearing 'handicap' until well-designed speech recognition in [...]

Details

Language :
English
ISSN :
10924388
Volume :
64
Issue :
8
Database :
Gale General OneFile
Journal :
Journal of Speech, Language, and Hearing Research
Publication Type :
Academic Journal
Accession number :
edsgcl.673449321
Full Text :
https://doi.org/10.1044/2021_JSLHR-20-00453