Back to Search Start Over

Quantitative Assessment of Immunohistochemistry Laboratory Performance by Measuring Analytic Response Curves and Limits of Detection

Authors :
Sompuram, Seshi R.
Vani, Kodela
Schaedle, Anika K.
Balasubramanian, Anuradha
Bogen, Steven A.
Source :
Archives of Pathology & Laboratory Medicine. July, 2018, Vol. 142 Issue 7, p851, 12 p.
Publication Year :
2018

Abstract

Context.--Numerous studies highlight interlaboratory performance variability in diagnostic immunohistochemistry (IHC) testing. Despite substantial improvements over the years, the inability to quantitatively and objectively assess immunostain sensitivity complicates interlaboratory standardization. Objective.--To quantitatively and objectively assess the sensitivity of the immunohistochemical stains for human epidermal growth factor receptor type 2 (HER2), estrogen receptor (ER), and progesterone receptor (PR) across IHC laboratories in a proficiency testing format. We measure sensitivity with parameters that are new to the field of diagnostic IHC: analytic response curves and limits of detection. Design.--Thirty-nine diagnostic IHC laboratories stained a set of 3 slides, one each for HER2, ER, and PR. Each slide incorporated a positive tissue section and IHControls at 5 different concentrations. The IHControls comprise cell-sized clear microbeads coated with defined concentrations of analyte (HER2, ER, and/or PR). The laboratories identified the limits of detection and then mailed the slides for quantitative assessment. Results.--Each commercial immunostain demonstrated a characteristic analytic response curve, reflecting strong reproducibility among IHC laboratories using the same automation and reagents prepared per current Good Manufacturing Practices. However, when comparing different commercial vendors (using different reagents), the data reveal up to 100-fold differences in analytic sensitivity. For proficiency testing purposes, quantitative assessment using analytic response curves was superior to subjective interpretation of limits of detection. Conclusions.--Assessment of IHC laboratory performance by quantitative measurement of analytic response curves is a powerful, objective tool for identifying outlier IHC laboratories. It uniquely evaluates immunostain performance across a range of defined analyte concentrations. (Arch Pathol Lab Med. 2018;142:851-862; doi: 10.5858/arpa.2017-0330-OA)<br />Discrepancies in patient testing among diagnostic immunohistochemistry (IHC) laboratories present a continuing challenge to individual laboratories and the field at large. (1-4) These discrepancies are especially important for companion diagnostics, [...]

Details

Language :
English
ISSN :
15432165
Volume :
142
Issue :
7
Database :
Gale General OneFile
Journal :
Archives of Pathology & Laboratory Medicine
Publication Type :
Academic Journal
Accession number :
edsgcl.550301157
Full Text :
https://doi.org/10.5858/arpa.2017-0330-OA