Accuracy and trending ability of the fourth-generation FloTrac/Vigileo System[TM] in patients undergoing abdominal aortic aneurysm surgery

Authors :
Maeda, Takuma
Hattori, Kohshi
Sumiyoshi, Miho
Kanazawa, Hiroko
Ohnishi, Yoshihiko
Source :
Journal of Anesthesia. June, 2018, Vol. 32 Issue 3, p387, 7 p.
Publication Year :
2018

Abstract

Purpose The fourth-generation FloTrac/Vigileo[TM] improved its algorithm to follow changes in systemic vascular resistance index (SVRI). This revision may improve the accuracy and trending ability of CI even in patients who undergo abdominal aortic aneurysm (AAA) surgery which cause drastic change of SVRI by aortic clamping. The purpose of this study is to elucidate the accuracy and trending ability of the fourth-generation FloTrac/Vigileo[TM] in patients with AAA surgery by comparing the FloTrac/Vigileo[TM]-derived CI (CI.sub.FT) with that measured by three-dimensional echocardiography (CI.sub.3D). Methods Twenty-six patients undergoing elective AAA surgery were included in this study. CI.sub.FT and CI3.sub.D were determined simultaneously in eight points including before and after aortic clamp. We used CI.sub.3D as the reference method. Results In the Bland-Altman analysis, CI.sub.FT had a wide limit of agreement with CI.sub.3D showing a percentage error of 46.7%. Subgroup analysis showed that the percentage error between CO.sub.3D and CO.sub.FT was 56.3% in patients with cardiac index < 2.5 L/min/m.sup.2 and 28.4% in patients with cardiac index [greater than or equal to] 2.5 L/min/m.sup.2. SVRI was significantly higher in patients with cardiac index < 2.5 L/min/m.sup.2 (1703 ± 330 vs. 2757 ± 798; p < 0.001). The tracking ability of fourth generation of FloTrac/Vigileo[TM] after aortic clamp was not clinically acceptable (26.9%). Conclusions The degree of accuracy of the fourth-generation FloTrac/Vigileo[TM] in patients with AAA surgery was not acceptable. The tracking ability of the fourth-generation FloTrac/Vigileo[TM] after aortic clamp was below the acceptable limit.<br />Author(s): Takuma Maeda [sup.1] [sup.2] , Kohshi Hattori [sup.3] , Miho Sumiyoshi [sup.1] , Hiroko Kanazawa [sup.1] , Yoshihiko Ohnishi [sup.1] Author Affiliations: (Aff1) 0000 0004 0378 8307, grid.410796.d, Department [...]

Details

Language :
English
ISSN :
09138668
Volume :
32
Issue :
3
Database :
Gale General OneFile
Journal :
Journal of Anesthesia
Publication Type :
Academic Journal
Accession number :
edsgcl.540830781
Full Text :
https://doi.org/10.1007/s00540-018-2491-y