Back to Search Start Over

The influence of interscalene block technique on adverse hemodynamic events

Authors :
Gianesello, Lara
Magherini, Manuela
Pavoni, Vittorio
Horton, Andrew
Nella, Alessandra
Campolo, Maria Consolata
Source :
Journal of Anesthesia. June 1, 2014, Vol. 28 Issue 3, p407, 6 p.
Publication Year :
2014

Abstract

Introduction Interscalene block (ISB) is regarded as an effective anesthetic technique for arthroscopic shoulder surgery [1]. Complications associated with ISB are well documented [2] and include blockade of the phrenic [...]<br />Purpose A hemodynamic event such as hypertension after interscalene block (ISB) is a complication that is often overlooked. The irregular spread of local anesthetic would cause a blockade of carotid sinus baroreceptors leading to the adverse event. The purpose of the present study is to compare ultrasound and neurostimulation technique in preventing hypertension after ISB. Methods Thirty patients without hypertension history who underwent arthroscopic shoulder surgery for a rotator cuff tear were enrolled. After preoperative administration of the State Trait Anxiety Inventory questionnaire, patients were allocated to receive ultrasound-guided ISB with 20 ml levobupivacaine-HCl 0.5% (group US) and 40 ml levobupivacaine-HCl 0.5% with neurostimulation (group NS). The need for antihypertensive drug was recorded. Block onset sensory and motor times were assessed. Systolic and diastolic blood pressures, and heart rate and pulse oximetry (Sp[O.sub.2]), were evaluated before the block as well as 2, 5, 10, 15, 20, and 30 min after. Results No differences in patient characteristics and anxiety were found in the two groups. Block onset times were similar. At 15 min after block placement, group NS showed significantly higher systolic and diastolic blood pressures compared to group US. No differences in heart rate and Sp[O.sub.2] were found between the two groups. Three patients of group NS required urapidil administration because of hypertension. Conclusions Ultrasound-guided ISB permits the use of a low volume of local anesthetic and seems to reduce the incidence of hypertension. Keywords Hypertension * Nerve stimulation * Ultrasonography * Interscalene brachial plexus block

Details

Language :
English
ISSN :
09138668
Volume :
28
Issue :
3
Database :
Gale General OneFile
Journal :
Journal of Anesthesia
Publication Type :
Academic Journal
Accession number :
edsgcl.378103426
Full Text :
https://doi.org/10.1007/s00540-013-1748-8