Back to Search Start Over

Effects of varying pulse parameters on ion homeostasis, cellular integrity, and force following electroporation of rat muscle in vivo

Authors :
Gissel, Hanne
Source :
The American Journal of Physiology. April, 2010, Vol. 298 Issue 4, pR918, 12 p.
Publication Year :
2010

Abstract

Electroporation is a technique used in vitro, ex vivo, and in vivo to permeabilize cell membranes. The effect on the tissue describes a continuum ranging from mild perturbations to massive tissue damage. Thus care should be taken when choosing pulses for a given application. Here the effects of electroporation paradigms ranging from severe to very gentle permeabilization were investigated on soleus, mainly composed of slow-twitch fibers, and extensor digitorum longus (EDL) and tibialis anterior (TA), almost exclusively composed of fast-twitch fibers. Five key physiological parameters were studied: force, muscle [Na.sup.+], [K.sup.+], and [Ca.sup.2+] content, and plasma lactate dehydrogenase activity. Four-week-old Wistar rats were anesthetized, and the lower part of the hind leg was electroporated. Blood samples were collected from the tail vein, and at the times indicated animals were killed and TA, EDL, and soleus muscles were collected for analysis of force and ion contents. Muscles were given eight high-voltage pulses of 100-[micro]s duration (8HV) at varying field intensity, one short high-voltage pulse combined with one long low-voltage pulse (HVLV), or eight medium-voltage pulses of 20-ms duration (8MV). Intensity of the electrical field strength was determinant for the degree of changes observed in the muscle. Field strengths below 300 V/cm did not give rise to measurable changes, whereas 8HV pulses at high field intensities (1,200 V/cm) caused severe and long-lasting damage to the muscle. Interestingly, the damage was more pronounced in EDL and TA compared with soleus, possibly because of the difference in fiber type composition. HVLV only caused temporary changes, with force and ion content being normalized by 4 h, suggesting that this pulse combination may be useful for the introduction of ions and molecules (e.g., DNA) into muscle cells. electropermeabilization; extensor digitorum longus; tibialis anterior; soleus; fiber type doi: 10.1152/ajpregu.00692.2009.

Details

Language :
English
ISSN :
00029513
Volume :
298
Issue :
4
Database :
Gale General OneFile
Journal :
The American Journal of Physiology
Publication Type :
Academic Journal
Accession number :
edsgcl.224166943