Back to Search
Start Over
Application of high-energy photon CT system with laser-Compton scattering to non-destructive test
- Source :
- IEEE Transactions on Nuclear Science. Dec, 2008, Vol. 55 Issue 6, p3571, 8 p.
- Publication Year :
- 2008
-
Abstract
- A computed tomography (CT) system using high-energy monochromatic photons is one of the best choices for non-destructive tests, to detect flaws or defects in manufactured items for the purpose of improving quality control, and quality assurance. We have developed such a CT system based on laser-Compton X-rays, which were generated with an electron accelerator and a laser beam. Using 10 MeV laser-Compton X-rays, an experimental study for non-destructive tests of concrete specimens with computed tomography were performed. We successfully obtained CT images. Index Terms--Computed tomography, electron accelerator, gamma-ray, laser-Compton, non-destructive test.