Back to Search Start Over

Effects of initial-fixed charge density on pH-sensitive hydrogels subjected to coupled pH and electric field stimuli: a meshless analysis

Authors :
Ng, T.Y.
Li, Hua
Yew, Y.K.
Lam, K.Y.
Source :
Journal of Biomechanical Engineering. April, 2007, Vol. 129 Issue 2, p148, 8 p.
Publication Year :
2007

Abstract

In this paper, we study the effects of initial fixed-charge density on the response behavior of pH-sensitive hydrogels subjected to coupled stimuli, namely, solution pH and externally applied electric,field. This is the first instance in which a coupled stimuli numerical analysis has been carried out for these polymer gels, which are used as active sensing/actuating elements in advanced biomicroelectromechanical systems devices. In this work, a chemo-electro-mechanical formulation, termed the multi-effect-coupling pH-stimulus (MECpH) model is first presented. This mathematical model takes into account the ionic species diffusion, electric potential coupling, and large mechanical deformation. In addition, a correlation between the diffusive hydrogen ions and fixed-charge groups on the hydrogel polymeric chains is established based on the Langmuir absorption isotherm, and incorporated accordingly into the MECpH model. To solve the resulting highly nonlinear and highly coupled partial differential equations of this mathematical model the Hermite-Cloud method, a novel true meshless technique, is employed. To demonstrate the accuracy and robustness the MECpH model computed numerical results are compared with experimental data available from literature. Following this validation, several numerical studies are carried out to investigate the effects of initial fixed-charge density on the volumetric variations of these pH-stimulus-responsive hydrogels when immersed in buffered solutions. [DOI: 10.1115/1.2472370] Keywords: bioMEMS, pH-sensitive hydrogel, chemo-electro-mechanical coupling, ionic species diffusion, electric potential coupling, MECpH model meshless method

Details

Language :
English
ISSN :
01480731
Volume :
129
Issue :
2
Database :
Gale General OneFile
Journal :
Journal of Biomechanical Engineering
Publication Type :
Academic Journal
Accession number :
edsgcl.162790361