Back to Search
Start Over
Method of measuring Bacillus anthracis spores in the presence of copious amounts of Bacillus thuringiensis and Bacillus cereus
- Source :
- Analytical Chemistry. Feb 1, 2007, Vol. 79 Issue 3, p1145, 8 p.
- Publication Year :
- 2007
-
Abstract
- A sensitive and reliable method for the detection of Bacillus anthracis (BA; Sterne strain 7702) spores in presence of large amounts of Bacillus thuringiensis (BT) and Bacillus cereus (BC) is presented based on a novel PZT-anchored piezoelectric excited millimeter-sized cantilever (PAPEMC) sensor with a sensing area of 1.5 [mm.sup.2]. Antibody (anti-BA) specific to BA spores was immobilized on the sensing area and exposed to various samples of BA, BT, and BC containing the same concentration of BA at 333 spores/mL, and the concentration of BT + BC was varied in concentration ratios of (BA:BT + BC) 0:1, 1:0, 1:1, 1:10, 1:100, and 1:1000. In each case, the sensor responded with an exponential decrease in resonant frequency and the steady-state frequency changes reached were 14 [+ or -] 31 (n = 11), 2742 [+ or -] 38 (n = 3), 3053 [+ or -] 19 (n = 2), 2777 [+ or -] 26 (n = 2), 2953 [+ or -] 24 (n = 2), and 3105 [+ or -] 27 (n = 2) Hz, respectively, in 0, 27, 45, 63, 154, and 219 min. The bound BA spores were released in each experiment, and the sensor response was nearly identical to the frequency change during attachment. These results suggest that the transport of BA spores to the antibody immobilized surface was hindered by the presence of other Bacillus species. The observed binding rate constant, based on the Langmuir kinetic model, was determined to be 0.15 [min.sup.-1]. A hindrance factor (6) is defined to describe the reduced attachment rate in the presence of BT + BC and found to increase exponentially with BT and BC concentration. The hindrance factor increased from 3.52 at 333 BT + BC spores/mL to 11.04 at 3.33 x [10.sup.5] BT + BC spores/mL, suggesting that [alpha] is a strong function of BT and BC concentration. The significance of these results is that anti-BA functionalized PEMC sensors are highly selective to Bacillus anthracis spores and the presence of other Bacillus species, in large amounts, does not prevent binding but impedes BA transport to the sensor.
Details
- Language :
- English
- ISSN :
- 00032700
- Volume :
- 79
- Issue :
- 3
- Database :
- Gale General OneFile
- Journal :
- Analytical Chemistry
- Publication Type :
- Academic Journal
- Accession number :
- edsgcl.159391133