Effects of cyclic pulsed operation on the coil performance in the Nb3Sn demo poloidal coil (DPC-EX)
- Source :
- IEEE Transactions on Magnetics. July, 1994, Vol. 30 Issue 4, p2535, 4 p.
- Publication Year :
- 1994
-
Abstract
- The effect of cyclic pulsed operation on the coil performance was studied from the electrical and mechanical points of view in the second experiment of the [Nb.sub.3]Sn Demo Poloidal Coil (DPC-EX). Current sharing temperatures, ac losses, displacements, and strains were measured before and after cyclic pulsed operation, which consisted of about 350 cycles. No degradation of the electrical and mechanical performance of the DPC-EX was observed in the range of these cycles.
Details
- ISSN :
- 00189464
- Volume :
- 30
- Issue :
- 4
- Database :
- Gale General OneFile
- Journal :
- IEEE Transactions on Magnetics
- Publication Type :
- Academic Journal
- Accession number :