Back to Search Start Over

An Experimental Anodized Titanium Surface for Transgingival Dental Implant Elements—Preliminary Report

Authors :
Jakub Hadzik
Paweł Kubasiewicz-Ross
Tomasz Gębarowski
Natalia Waloszczyk
Artur Maciej
Agnieszka Stolarczyk
Tomasz Gedrange
Marzena Dominiak
Ernest Szajna
Wojciech Simka
Source :
Journal of Functional Biomaterials, Vol 14, Iss 1, p 34 (2023)
Publication Year :
2023
Publisher :
MDPI AG, 2023.

Abstract

The characteristics such as microtopography, physical and chemical properties influence the behavior of an implant in a soft tissue. Anodization—as a potent method of titanium alloy surface modification—of the transgingival abutment or healing screw, has achieved some improvement. One of the possible surface treatment method is low-pressure radiofrequency oxygen plasma treatment. The aim of the study was to evaluate the chemical properties and cytocompatibility of the experimental surface. Titanium discs made of grade-23 titanium alloy (Ti-6Al-4V) anodized (A sample) with different voltage parameters (28, 67, 78, and 98 V) were included in the study. Half of the samples regarded as the “S” group were additionally treated with low-pressure radiofrequency oxygen plasma treatment. The surfaces were characterized using scanning electron microscopy, X-ray spectroscopy and Raman spectroscopy, and electrochemically investigated via a corrosion test. Furthermore, two cell lines were used, including the CHO-compatible reference line and a primary human fibroblast line for the MTT assay; direct (contact) cytotoxicity of the materials was tested with the cells, and the growth of fibroblasts on the surfaces of the different materials was tested. The morphology of the “S”-treated samples did not differ from the morphology of only-anodized samples. However, the oxygen concentration on the surface in that group slightly increased by about 1% as a result of post-trial treatment. The highest corrosion resistance was observed for both A-78 V and S-78 V samples. The cytotoxicity assay revealed no changes in cell morphology or vitality. The MTT test proved comparable culture viability among all groups; however, the “S” samples showed statistically significantly higher fibroblast proliferation and adhesion scores compared to the “A” samples. Through the in vitro study, the low-pressure radiofrequency oxygen plasma treatment of the anodized Ti-6Al-4V alloy presented itself as an auspicious option in the field of transgingival element surface modification of implants.

Details

Language :
English
ISSN :
20794983
Volume :
14
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Journal of Functional Biomaterials
Publication Type :
Academic Journal
Accession number :
edsdoj.ff554fd799be40f29a21283a59594607
Document Type :
article
Full Text :
https://doi.org/10.3390/jfb14010034