Back to Search Start Over

Polydopamine (PDA) coatings with endothelial vascular growth factor (VEGF) immobilization inhibiting neointimal formation post zinc (zn) wire implantation in rat aortas

Authors :
Jiayin Fu
Qiongjun Zhu
Zhezhe Chen
Jing Zhao
Shaofei Wu
Meng Zhao
Shihui Xu
Dongwu Lai
Guosheng Fu
Wenbin Zhang
Source :
Biomaterials Research, Vol 27, Iss 1, Pp 1-17 (2023)
Publication Year :
2023
Publisher :
American Association for the Advancement of Science (AAAS), 2023.

Abstract

Abstract Background Bioresorbable stents are designed to provide temporary mechanical support to the coronary arteries and then slowly degrade in vivo to avoid chronic inflammation. Zinc (Zn) is a promising material for bioresorbable stents; However, it can cause inflammation and neointimal formation after being implanted into blood vessels. Methods To improve biocompatibility of Zn, we first coated it with polydopamine (PDA), followed by immobilization of endothelial vascular growth factor (VEGF) onto the PDA coatings. Adhesion, proliferation, and phenotype maintenance of endothelial cells (ECs) on the coated Zn were evaluated in vitro. Then, a wire aortic implantation model in rats mimicking endovascular stent implantation in humans was used to assess vascular responses to the coated Zn wires in vivo. Thrombosis in aortas post Zn wire implantation, degradation of Zn wires in vivo, neointimal formation surrounding Zn wires, and macrophage infiltration and extracellular matrix (ECM) remodeling in the neointimas were examined. Results In vitro data showed that the PDA-coated Zn encouraged EC adhesion, spreading, proliferation, and phenotype maintenance on its surfaces. VEGF functionalization on PDA coatings further enhanced the biocompatibility of Zn to ECs. Implantation of PDA-coated Zn wires into rat aortas didn’t cause thrombosis and showed a faster blood flow than pure Zn or the Zn wires coated with VEGF alone. In addition, the PDA coating didn’t affect the degradation of Zn wires in vivo. Besides, the PDA-coated Zn wires reduced neointimal formation, increased EC coverage, decreased macrophage infiltration, and declined aggrecan accumulation in ECM. VEGF immobilization onto PDA coatings didn’t cause thrombosis and affect Zn degradation in vivo as well, and further increased the endothelization percentage as compared to PDA coating alone, thus resulting in thinner neointimas. Conclusion These results indicate that PDA coatings with VEGF immobilization would be a promising approach to functionalize Zn surfaces to increase biocompatibility, reduce inflammation, and inhibit neointimal formation after Zn implantation in vivo. Graphical Abstract

Details

Language :
English
ISSN :
20557124
Volume :
27
Issue :
1
Database :
Directory of Open Access Journals
Journal :
Biomaterials Research
Publication Type :
Academic Journal
Accession number :
edsdoj.ff0415b74adf4349aae592f548a546ef
Document Type :
article
Full Text :
https://doi.org/10.1186/s40824-023-00423-5