Back to Search Start Over

Characterization of extracellular vesicles and synthetic nanoparticles with four orthogonal single‐particle analysis platforms

Authors :
Tanina Arab
Emily R. Mallick
Yiyao Huang
Liang Dong
Zhaohao Liao
Zezhou Zhao
Olesia Gololobova
Barbara Smith
Norman J. Haughey
Kenneth J. Pienta
Barbara S. Slusher
Patrick M. Tarwater
Juan Pablo Tosar
Angela M. Zivkovic
Wyatt N. Vreeland
Michael E. Paulaitis
Kenneth W. Witwer
Source :
Journal of Extracellular Vesicles, Vol 10, Iss 6, Pp n/a-n/a (2021)
Publication Year :
2021
Publisher :
Wiley, 2021.

Abstract

Abstract We compared four orthogonal technologies for sizing, counting, and phenotyping of extracellular vesicles (EVs) and synthetic particles. The platforms were: single‐particle interferometric reflectance imaging sensing (SP‐IRIS) with fluorescence, nanoparticle tracking analysis (NTA) with fluorescence, microfluidic resistive pulse sensing (MRPS), and nanoflow cytometry measurement (NFCM). EVs from the human T lymphocyte line H9 (high CD81, low CD63) and the promonocytic line U937 (low CD81, high CD63) were separated from culture conditioned medium (CCM) by differential ultracentrifugation (dUC) or a combination of ultrafiltration (UF) and size exclusion chromatography (SEC) and characterized by transmission electron microscopy (TEM) and Western blot (WB). Mixtures of synthetic particles (silica and polystyrene spheres) with known sizes and/or concentrations were also tested. MRPS and NFCM returned similar particle counts, while NTA detected counts approximately one order of magnitude lower for EVs, but not for synthetic particles. SP‐IRIS events could not be used to estimate particle concentrations. For sizing, SP‐IRIS, MRPS, and NFCM returned similar size profiles, with smaller sizes predominating (per power law distribution), but with sensitivity typically dropping off below diameters of 60 nm. NTA detected a population of particles with a mode diameter greater than 100 nm. Additionally, SP‐IRIS, MRPS, and NFCM were able to identify at least three of four distinct size populations in a mixture of silica or polystyrene nanoparticles. Finally, for tetraspanin phenotyping, the SP‐IRIS platform in fluorescence mode was able to detect at least two markers on the same particle, while NFCM detected either CD81 or CD63. Based on the results of this study, we can draw conclusions about existing single‐particle analysis capabilities that may be useful for EV biomarker development and mechanistic studies.

Details

Language :
English
ISSN :
20013078
Volume :
10
Issue :
6
Database :
Directory of Open Access Journals
Journal :
Journal of Extracellular Vesicles
Publication Type :
Academic Journal
Accession number :
edsdoj.fd746bab0cb349b79fa923c7436a96ca
Document Type :
article
Full Text :
https://doi.org/10.1002/jev2.12079