Back to Search Start Over

Missed Down Syndrome Cases after First Trimester False-Negative Screening—Lessons to be Learned

Authors :
Anca Angela Simionescu
Ana Maria Alexandra Stanescu
Source :
Medicina, Vol 56, Iss 4, p 199 (2020)
Publication Year :
2020
Publisher :
MDPI AG, 2020.

Abstract

Background and Objectives: Here, we performed a descriptive analysis of Down syndrome (DS) cases that were misdiagnosed and/or false-negative diagnosed after first trimester traditional screening via risk evaluation using ultrasound, biochemical markers, and different software programs. Our objective was to demonstrate the clear need to improve the application of prenatal DS screening programs using standardized ultrasound measurements, accurate pregnancy dating, analytical immunoassay performance, and properly selected medians. Materials and Methods: We performed a database search for the period 2010–2015 to analyze DS cases that were false-negative diagnosed after the first trimester of pregnancy, before the introduction of cell free fetal DNA-based tests by Romanian laboratories in 2015. First-trimester screening was performed using two software programs for prenatal DS risk calculation: Astraia and Prisca. The rationale for using both software programs was to assess the full risk using the maternal age combined test (based on nuchal translucency thickness, nasal bone, ductus venosus flow, tricuspid flow, free beta-human chorionic gonadotropin level, and serum pregnancy-associated plasma protein-A) and, in some cases, the triple test. Results: We identified seven DS cases that exhibited low risk for trisomy 21, and 6540 cases with a low risk for trisomy 21 and euploid fetus in the first trimester. Using Astraia software, 14 cases were diagnosed, and three cases were missed after risk calculation. Using Prisca software, four cases were missed. Additionally, one neonate had a missed prenatal diagnosis of atrio-ventricular canal defect. Conclusion: In Romania, the evaluation of DS risk depends on patient choice (without knowing the accuracy of the utilized tests) and on the operators’ skills. Both Astraia and Prisca software were developed by experts, who can prove their performance in DS screening. However, even in an ideal situation, false-negative results are possible. The application of first and second-trimester combined screening based on biochemical markers could be improved by the implementation of standardized protocols, professional guidelines for test application, and audit control.

Details

Language :
English
ISSN :
56040199, 16489144, and 1010660X
Volume :
56
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Medicina
Publication Type :
Academic Journal
Accession number :
edsdoj.fd5513ee1c54419bb03d8f232278ca7
Document Type :
article
Full Text :
https://doi.org/10.3390/medicina56040199