Back to Search Start Over

Nucleocapsid (N) Gene Mutations of SARS-CoV-2 Can Affect Real-Time RT-PCR Diagnostic and Impact False-Negative Results

Authors :
Jéssika Cristina Chagas Lesbon
Mirele Daiana Poleti
Elisângela Chicaroni de Mattos Oliveira
José Salvatore Leister Patané
Luan Gaspar Clemente
Vincent Louis Viala
Gabriela Ribeiro
Marta Giovanetti
Luiz Carlos Junior de Alcantara
Olivia Teixeira
Maria Cristina Nonato
Loyze Paola Oliveira de Lima
Antonio Jorge Martins
Claudia Renata dos Santos Barros
Elaine Cristina Marqueze
Jardelina de Souza Todão Bernardino
Debora Botequio Moretti
Ricardo Augusto Brassaloti
Raquel de Lello Rocha Campos Cassano
Pilar Drummond Sampaio Correa Mariani
Svetoslav Nanev Slavov
Rafael Bezerra dos Santos
Evandra Strazza Rodrigues
Elaine Vieira Santos
Josiane Serrano Borges
Debora Glenda Lima de La Roque
Joao Paulo Kitajima
Bibiana Santos
Patricia Akemi Assato
Felipe Allan da Silva da Costa
Cecilia Artico Banho
Livia Sacchetto
Marilia Mazzi Moraes
Melissa Palmieri
Fabiana Erica Vilanova da Silva
Rejane Maria Tommasini Grotto
Jayme A. Souza-Neto
Mauricio Lacerda Nogueira
Luiz Lehman Coutinho
Rodrigo Tocantins Calado
Raul Machado Neto
Dimas Tadeu Covas
Simone Kashima
Maria Carolina Elias
Sandra Coccuzzo Sampaio
Heidge Fukumasu
Source :
Viruses, Vol 13, Iss 12, p 2474 (2021)
Publication Year :
2021
Publisher :
MDPI AG, 2021.

Abstract

The current COVID-19 pandemic demands massive testing by Real-time RT-PCR (Reverse Transcription Polymerase Chain Reaction), which is considered the gold standard diagnostic test for the detection of the SARS-CoV-2 virus. However, the virus continues to evolve with mutations that lead to phenotypic alterations as higher transmissibility, pathogenicity or vaccine evasion. Another big issue are mutations in the annealing sites of primers and probes of RT-PCR diagnostic kits leading to false-negative results. Therefore, here we identify mutations in the N (Nucleocapsid) gene that affects the use of the GeneFinder COVID-19 Plus RealAmp Kit. We sequenced SARS-CoV-2 genomes from 17 positive samples with no N gene detection but with RDRP (RNA-dependent RNA polymerase) and E (Envelope) genes detection, and observed a set of three different mutations affecting the N detection: a deletion of 18 nucleotides (Del28877-28894), a substitution of GGG to AAC (28881-28883) and a frameshift mutation caused by deletion (Del28877-28878). The last one cause a deletion of six AAs (amino acids) located in the central intrinsic disorder region at protein level. We also found this mutation in 99 of the 14,346 sequenced samples by the Sao Paulo state Network for Pandemic Alert of Emerging SARS-CoV-2 variants, demonstrating the circulation of the mutation in Sao Paulo, Brazil. Continuous monitoring and characterization of mutations affecting the annealing sites of primers and probes by genomic surveillance programs are necessary to maintain the effectiveness of the diagnosis of COVID-19.

Details

Language :
English
ISSN :
19994915
Volume :
13
Issue :
12
Database :
Directory of Open Access Journals
Journal :
Viruses
Publication Type :
Academic Journal
Accession number :
edsdoj.fb160f13d364195bbddeb0c2e2ef3b1
Document Type :
article
Full Text :
https://doi.org/10.3390/v13122474