Back to Search Start Over

Amperometric Biosensor for Pesticide Methamidophos Assay

Authors :
Miroslav Pohanka
Kamil Kuča
Daniel Jun
Source :
Acta Medica, Vol 50, Iss 4, Pp 239-241 (2007)
Publication Year :
2007
Publisher :
Karolinum Press, 2007.

Abstract

Amperometric biosensor based on enzyme acetylcholinesterase (AChE; EC 3.1.1.7) was tested for pesticide methamidophos assay. Biosensor consists from four screen printed platinum electrodes on ceramic strip. AChE was physically adsorbed onto the electrode surface. The measuring principle was based on the inhibition of AChE activity in the presence of methamidophos. The proposed method limit of detection was 2.45 nM, responding to 3.46 pg of methamidophos detected absolutely when we consider the sample volume.

Details

Language :
English
ISSN :
18059694 and 12114286
Volume :
50
Issue :
4
Database :
Directory of Open Access Journals
Journal :
Acta Medica
Publication Type :
Academic Journal
Accession number :
edsdoj.fb007e4aa42b46278126585a17200735
Document Type :
article
Full Text :
https://doi.org/10.14712/18059694.2017.91