Back to Search Start Over

Uso do 'swab' de algodão para colpocitologia Use of the cotton swab in cervical cytology

Authors :
Álvaro Luiz Lage Alves
Source :
Revista Brasileira de Ginecologia e Obstetrícia, Vol 21, Iss 7, Pp 401-405 (1999)
Publication Year :
1999
Publisher :
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia, 1999.

Abstract

Objetivos: investigar se a adição do swab de algodão à espátula de Ayre e o seu prévio umedecimento com solução salina fisiológica aumentam a obtenção de células endocervicais nos esfregaços colpocitológicos. Métodos: foi realizado um estudo diagnóstico, randômico e simples cego envolvendo três técnicas de colheita (espátula de Ayre, combinação espátula de Ayre-swab de algodão seco e combinação espátula de Ayre-swab de algodão úmido). Foram avaliados 307 esfregaços preparados por estudantes de Medicina e residentes de Ginecologia e Obstetrícia. Resultados: não houve aumento significativo na obtenção de células endocervicais (colunares e/ou metaplásicas), nem com a adição do "swab" seco (p = 0,2), tampouco com a do swab umidecido (p = 0,8). Conclusões: concluiu-se que, principalmente quando as colheitas forem realizadas por profissionais em treinamento e na ausência de outro dispositivo de coleta endocervical mais eficiente, é mais econômico utilizar apenas a espátula de Ayre no preparo do esfregaço.Purpose: to investigate if the addition of a cotton "swab" to the Ayre spatula and its previous moistening with physiologic saline solution increase the obtention of endocervical cells in colpocytologic smears. Methods: a random and single-blind diagnostic study was performed, involving three techniques of collection (Ayre spatula, combination of Ayre-dry cotton swab spatula and combination of Ayre-moist cotton swab spatula). A total of 307 smears prepared by Medicine students and residents of Gynecology and Obstetrics were evaluated. Results: there was no significant increase in the number of endocervical cells (columnar and/or metaplastic), obtained with the addition of dry swab (p = 0.2) or with the addition of a moistened swab (p = 0.8). Conclusions: the author concluded that mainly when the collections were performed by trainee professionals and in the absence of other more effective endocervical collecting device, it is more economical to use only the Ayre spatula to prepare the smear.

Details

Language :
English, Portuguese
ISSN :
01007203
Volume :
21
Issue :
7
Database :
Directory of Open Access Journals
Journal :
Revista Brasileira de Ginecologia e Obstetrícia
Publication Type :
Academic Journal
Accession number :
edsdoj.f84389531f3e44a5bd4019c709ff9560
Document Type :
article
Full Text :
https://doi.org/10.1590/S0100-72031999000700006