Back to Search Start Over

Extracellular Vesicle (EV) Array: microarray capturing of exosomes and other extracellular vesicles for multiplexed phenotyping

Authors :
Malene Jørgensen
Rikke Bæk
Shona Pedersen
Evo K.L. Søndergaard
Søren R. Kristensen
Kim Varming
Source :
Journal of Extracellular Vesicles, Vol 2, Iss 0, Pp 1-9 (2013)
Publication Year :
2013
Publisher :
Wiley, 2013.

Abstract

Background: Exosomes are one of the several types of cell-derived vesicles with a diameter of 30–100 nm. These extracellular vesicles are recognized as potential markers of human diseases such as cancer. However, their use in diagnostic tests requires an objective and high-throughput method to define their phenotype and determine their concentration in biological fluids. To identify circulating as well as cell culture-derived vesicles, the current standard is immunoblotting or a flow cytometrical analysis for specific proteins, both of which requires large amounts of purified vesicles. Methods: Based on the technology of protein microarray, we hereby present a highly sensitive Extracellular Vesicle (EV) Array capable of detecting and phenotyping exosomes and other extracellular vesicles from unpurified starting material in a high-throughput manner. To only detect the exosomes captured on the EV Array, a cocktail of antibodies against the tetraspanins CD9, CD63 and CD81 was used. These antibodies were selected to ensure that all exosomes captured are detected, and concomitantly excluding the detection of other types of microvesicles. Results: The limit of detection (LOD) was determined on exosomes derived from the colon cancer cell line LS180. It clarified that supernatant from only approximately 104 cells was needed to obtain signals or that only 2.5×104 exosomes were required for each microarray spot (~1 nL). Phenotyping was performed on plasma (1–10 µL) from 7 healthy donors, which were applied to the EV Array with a panel of antibodies against 21 different cellular surface antigens and cancer antigens. For each donor, there was considerable heterogeneity in the expression levels of individual markers. The protein profiles of the exosomes (defined as positive for CD9, CD63 and CD81) revealed that only the expression level of CD9 and CD81 was approximately equal in the 7 donors. This implies questioning the use of CD63 as a standard exosomal marker since the expression level of this tetraspanin was considerably lower.

Details

Language :
English
ISSN :
20013078
Volume :
2
Issue :
0
Database :
Directory of Open Access Journals
Journal :
Journal of Extracellular Vesicles
Publication Type :
Academic Journal
Accession number :
edsdoj.f7d879f3df2d4e558a9e122ac2c6a813
Document Type :
article
Full Text :
https://doi.org/10.3402/jev.v2i0.20920