Back to Search Start Over

Simulator-based ultrasound training for identification of endotracheal tube placement in a neonatal intensive care unit using point of care ultrasound

Authors :
Khushboo Qaim Ali
Sajid Bashir Soofi
Ali Shabbir Hussain
Uzair Ansari
Shaun Morris
Mark Oliver Tessaro
Shabina Ariff
Hasan Merali
Source :
BMC Medical Education, Vol 20, Iss 1, Pp 1-11 (2020)
Publication Year :
2020
Publisher :
BMC, 2020.

Abstract

Abstract Background Simulators are an extensively utilized teaching tool in clinical settings. Simulation enables learners to practice and improve their skills in a safe and controlled environment before using these skills on patients. We evaluated the effect of a training session utilizing a novel intubation ultrasound simulator on the accuracy of provider detection of tracheal versus esophageal neonatal endotracheal tube (ETT) placement using point-of-care ultrasound (POCUS). We also investigated whether the time to POCUS image interpretation decreased with repeated simulator attempts. Methods Sixty neonatal health care providers participated in a three-hour simulator-based training session in the neonatal intensive care unit (NICU) of Aga Khan University Hospital (AKUH), Karachi, Pakistan. Participants included neonatologists, neonatal fellows, pediatric residents and senior nursing staff. The training utilized a novel low-cost simulator made with gelatin, water and psyllium fiber. Training consisted of a didactic session, practice with the simulator, and practice with intubated NICU patients. At the end of training, participants underwent an objective structured assessment of technical skills (OSATS) and ten rounds of simulator-based testing of their ability to use POCUS to differentiate between simulated tracheal and esophageal intubations. Results The majority of the participants in the training had an average of 7.0 years (SD 4.9) of clinical experience. After controlling for gender, profession, years of practice and POCUS knowledge, linear mixed model and mixed effects logistic regression demonstrated marginal improvement in POCUS interpretation over repeated simulator testing. The mean time-to-interpretation decreased from 24.7 (SD 20.3) seconds for test 1 to 10.1 (SD 4.5) seconds for Test 10, p

Details

Language :
English
ISSN :
14726920
Volume :
20
Issue :
1
Database :
Directory of Open Access Journals
Journal :
BMC Medical Education
Publication Type :
Academic Journal
Accession number :
edsdoj.f7c6f24b6bea4c508013691ef62138e3
Document Type :
article
Full Text :
https://doi.org/10.1186/s12909-020-02338-4