Back to Search Start Over

How Accurate Is Your Activity Tracker? A Comparative Study of Step Counts in Low-Intensity Physical Activities

Authors :
Alinia, Parastoo
Cain, Chris
Fallahzadeh, Ramin
Shahrokni, Armin
Cook, Diane
Ghasemzadeh, Hassan
Source :
JMIR mHealth and uHealth, Vol 5, Iss 8, p e106 (2017)
Publication Year :
2017
Publisher :
JMIR Publications, 2017.

Abstract

BackgroundAs commercially available activity trackers are being utilized in clinical trials, the research community remains uncertain about reliability of the trackers, particularly in studies that involve walking aids and low-intensity activities. While these trackers have been tested for reliability during walking and running activities, there has been limited research on validating them during low-intensity activities and walking with assistive tools. ObjectiveThe aim of this study was to (1) determine the accuracy of 3 Fitbit devices (ie, Zip, One, and Flex) at different wearing positions (ie, pants pocket, chest, and wrist) during walking at 3 different speeds, 2.5, 5, and 8 km/h, performed by healthy adults on a treadmill; (2) determine the accuracy of the mentioned trackers worn at different sites during activities of daily living; and (3) examine whether intensity of physical activity (PA) impacts the choice of optimal wearing site of the tracker. MethodsWe recruited 15 healthy young adults to perform 6 PAs while wearing 3 Fitbit devices (ie, Zip, One, and Flex) on their chest, pants pocket, and wrist. The activities include walking at 2.5, 5, and 8 km/h, pushing a shopping cart, walking with aid of a walker, and eating while sitting. We compared the number of steps counted by each tracker with gold standard numbers. We performed multiple statistical analyses to compute descriptive statistics (ie, ANOVA test), intraclass correlation coefficient (ICC), mean absolute error rate, and correlation by comparing the tracker-recorded data with that of the gold standard. ResultsAll the 3 trackers demonstrated good-to-excellent (ICC>0.75) correlation with the gold standard step counts during treadmill experiments. The correlation was poor (ICC

Details

Language :
English
ISSN :
22915222
Volume :
5
Issue :
8
Database :
Directory of Open Access Journals
Journal :
JMIR mHealth and uHealth
Publication Type :
Academic Journal
Accession number :
edsdoj.f74ee731f3b455eb5510c8ef3e26f1f
Document Type :
article
Full Text :
https://doi.org/10.2196/mhealth.6321