Back to Search Start Over

Breathing-induced Errors in Quantification and Description of Dominant Intra-Prostatic Lesions (Dils) in PET Images: A Simulation Study by Means of The 4D NCAT Phantom

Authors :
Khadijeh Bamneshin
Seied Rabi Mahdavi
Ahmad Bitarafan-Rajabi
Parham Geramifar
Payman Hejazi
Majid Jadidi
Source :
Journal of Biomedical Physics and Engineering, Vol 12, Iss 5, Pp 497-504 (2022)
Publication Year :
2022
Publisher :
Shiraz University of Medical Sciences, 2022.

Abstract

Background: Respiratory movement and the motion range of the diaphragm can affect the quality and quantity of prostate images.Objective: This study aimed to investigate the magnitude of respiratory-induced errors to determine Dominant Intra- prostatic Lesions (DILs) in positron emission tomography (PET) images.Material and Methods: In this simulation study, we employed the 4D NURBS-based cardiac-torso (4D-NCAT) phantom with a realistic breathing model to simulate the respiratory cycles of a patient to assess the displacement, volume, maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), signal to noise ratio (SNR), and the contrast of DILs in frames within the respiratory cycle.Results: Respiration in a diaphragm motion resulted in the maximum superior-inferior displacement of 3.9 and 6.1 mm, and the diaphragm motion amplitudes of 20 and 35 mm. In a no-motion image, the volume measurement of DILs had the smallest percentage of errors. Compared with the no-motion method, the percentages of errors in the average method in 20 and 35 mm- diaphragm motion were 25% and 105%, respectively. The motion effect was significantly reduced in terms of the values of SUVmax and SUVmean in comparison with the values of SUVmax and SUVmean in no- motion images. The contrast values in respiratory cycle frames were at a range of 3.3-19.2 mm and 6.5-46 for diaphragm movements’ amplitudes of 20 and 35 mm. Conclusion: The respiratory movement errors in quantification and delineation of DILs were highly dependent on the range of motion, while the average method was not suitable to precisely delineate DILs in PET/CT in the dose-painting technique.

Details

Language :
English
ISSN :
22517200
Volume :
12
Issue :
5
Database :
Directory of Open Access Journals
Journal :
Journal of Biomedical Physics and Engineering
Publication Type :
Academic Journal
Accession number :
edsdoj.f6d570ec9b654c73a99fc140028abb80
Document Type :
article
Full Text :
https://doi.org/10.31661/jbpe.v0i0.1912-1015