Back to Search
Start Over
Sit-to-stand test and 6-min walking test correlation in patients with chronic obstructive pulmonary disease
- Source :
- Annals of Thoracic Medicine, Vol 10, Iss 4, Pp 269-273 (2015)
- Publication Year :
- 2015
- Publisher :
- Wolters Kluwer Medknow Publications, 2015.
-
Abstract
- Background: The 6-min walking test (6MWT) is one of the most commonly used tests to assess exercise capacity during chronic obstructive pulmonary disease (COPD). However, it is a relatively time-consuming test. Many authors assessed the usefulness of simpler methods, as the sit-to-stand test (STST), to estimate exercise capacity. Purpose: To demonstrate the feasibility of STST, in comparison to 6MWT, for the evaluation of functional status in Tunisian COPD patients and evaluate its correlation to the severity of the disease. Methods: We studied patients with COPD (Global Initiative for Chronic Obstructive Lung Disease A-D). All patients had plethysmography and manual quadriceps femoris muscle strength evaluation. Each patient completed a 6MWT and a STST. During the tests, dyspnea severity (Borg scale), heart rate, pulsed oxygen saturation, and blood pressure were measured. Results: In 49 patients with stable COPD (mean age 67.06 ± 8.4 years, mean forced expiratory volume in the first second 46.25% ± 19.64%), 6MWT and STST were correlated with each other (r = 0.47, P = 0.001). During 6MWT and STST, the rise in heart rate, systolic blood pressure, and severity of dyspnea were statistically significant compared to baseline (P < 0.05). However, cardiorespiratory stress was lower after STST than after 6MWT (P < 0.05). A statistically significant positive correlation was noted between the 6MWT distance and forced vital capacity (r = 0.357, P < 0.05). The 6MWT was negatively correlated with dyspnea severity at baseline (r = −0.289, P < 0.05) and with BODE index (r = −0.672, P < 0.01). STST was correlated only with age (r = 0.377, P < 0.01). No correlation was found between both tests and quadriceps femoris strength. Conclusion: As like as 6MWT, STST can determine functional status during COPD. In addition, it is less time consuming and produces less hemodynamical stress compared to 6MWT. STST can be used as an alternative for 6MWT in patients with COPD.
Details
- Language :
- English
- ISSN :
- 18171737 and 19983557
- Volume :
- 10
- Issue :
- 4
- Database :
- Directory of Open Access Journals
- Journal :
- Annals of Thoracic Medicine
- Publication Type :
- Academic Journal
- Accession number :
- edsdoj.f560efbc0e8246bf85435fd51c749ca4
- Document Type :
- article
- Full Text :
- https://doi.org/10.4103/1817-1737.165289