Back to Search Start Over

Forensic Building: Deterioration and Defect in Concrete Structures

Authors :
Jamaluddin N.
Ayop S. S
Wan Ibrahim M. H.
Boon K. H.
Yeoh D.
Shahidan S.
Mohamad N.
Tuan Chik T. N.
Abd. Ghafar N. H.
Abdul Ghani A. H.
Shamrul-Mar S.
Source :
MATEC Web of Conferences, Vol 103, p 02016 (2017)
Publication Year :
2017
Publisher :
EDP Sciences, 2017.

Abstract

Forensic building is needed to examine the affected building structure components to assess the structural integrity. This paper highlights some of the studies involved on affected concrete structures in various building types where the non-destructive test (NDT) and destructive tests. The structural integrity can be evaluated based on the extent of deterioration from the experimental results for instance the cause of the corrode reinforcements was due to inadequate concrete cover, whereas the failure of the concrete wall was due to structures’ under design which leads to the collapse of the wall. The condition of the floor slab that experience vibration was assessed from the Laser Doppler Vibrator test (LDV). Based on the test results the peak acceleration of the particular floor slab is higher.

Details

Language :
English, French
ISSN :
2261236X
Volume :
103
Database :
Directory of Open Access Journals
Journal :
MATEC Web of Conferences
Publication Type :
Academic Journal
Accession number :
edsdoj.f441256e20fc4ae5bc399ec4eb6d4993
Document Type :
article
Full Text :
https://doi.org/10.1051/matecconf/201710302016