Back to Search Start Over

The predictive performance of SAPS 2 and SAPS 3 in an intermediate care unit for internal medicine at a German university transplant center; A retrospective analysis.

Authors :
Michael Jahn
Jan Rekowski
Guido Gerken
Andreas Kribben
Ali Canbay
Antonios Katsounas
Source :
PLoS ONE, Vol 14, Iss 9, p e0222164 (2019)
Publication Year :
2019
Publisher :
Public Library of Science (PLoS), 2019.

Abstract

OBJECTIVE:To analyze and compare the performance of the Simplified-Acute-Physiology-Score (SAPS) 2 and SAPS 3 among intermediate care patients with internal disorders. MATERIALS AND METHODS:We conducted a retrospective single-center analysis in patients (n = 305) admitted to an intermediate-care-unit (ImCU) for internal medicine at the University Hospital Essen, Germany. We employed and compared the SAPS 2 vs. the SAPS 3 scoring system for the assessment of disease severity and prediction of mortality rates among patients admitted to the ImCU within an 18-month period. Both scores, which utilize parameters recorded at admission to the intensive-care-unit (ICU), represent the most widely applied scoring systems in European intensive care medicine. The area-under-the-receiver-operating-characteristic-curve (AUROC) was used to evaluate the SAPS 2 and SAPS 3 discrimination performance. Ultimately, standardized-mortality-ratios (SMRs) were calculated alongside their respective 95%-confidence-intervals (95% CI) in order to determine the observed-to-expected death ratio and calibration belt plots were generated to evaluate the SAPS 2 and SAPS 3 calibration performance. RESULTS:Both scores provided acceptable discrimination performance, i.e., the AUROC was 0.71 (95% CI, 0.65-0.77) for SAPS 2 and 0.77 (95% CI, 0.72-0.82) for SAPS 3. Against the observed in-hospital mortality of 30.2%, SAPS 2 showed a weak performance with a predicted mortality of 17.4% and a SMR of 1.74 (95% CI, 1.38-2.09), especially in association with liver diseases and/or sepsis. SAPS 3 performed accurately, resulting in a predicted mortality of 29.9% and a SMR of 1.01 (95% CI, 0.8-1.21). Based on Calibration belt plots, SAPS 2 showed a poor calibration-performance especially in patients with low mortality risk (P

Subjects

Subjects :
Medicine
Science

Details

Language :
English
ISSN :
19326203
Volume :
14
Issue :
9
Database :
Directory of Open Access Journals
Journal :
PLoS ONE
Publication Type :
Academic Journal
Accession number :
edsdoj.f2ea2c6c03344a459634ae8937bec1de
Document Type :
article
Full Text :
https://doi.org/10.1371/journal.pone.0222164