Back to Search Start Over

Pupillometry Assessment of Speech Recognition and Listening Experience in Adult Cochlear Implant Patients

Authors :
Francesca Yoshie Russo
Michel Hoen
Chadlia Karoui
Thomas Demarcy
Marine Ardoint
Maria-Pia Tuset
Daniele De Seta
Olivier Sterkers
Ghizlène Lahlou
Isabelle Mosnier
Source :
Frontiers in Neuroscience, Vol 14 (2020)
Publication Year :
2020
Publisher :
Frontiers Media S.A., 2020.

Abstract

ObjectiveThe aim of the present study was to investigate the pupillary response to word identification in cochlear implant (CI) patients. Authors hypothesized that when task difficulty (i.e., addition of background noise) increased, pupil dilation markers such as the peak dilation or the latency of the peak dilation would increase in CI users, as already observed in normal-hearing and hearing-impaired subjects.MethodsPupillometric measures in 10 CI patients were combined to standard speech recognition scores used to evaluate CI outcomes, namely, speech audiometry in quiet and in noise at +10 dB signal-to-noise ratio (SNR). The main outcome measures of pupillometry were mean pupil dilation, maximal pupil dilation, dilation latency, and mean dilation during return to baseline or retention interval. Subjective hearing quality was evaluated by means of one self-reported fatigue questionnaire, and the Speech, Spatial, and Qualities (SSQ) of Hearing scale.ResultsAll pupil dilation data were transformed to percent change in event-related pupil dilation (ERPD, %). Analyses show that the peak amplitudes for both mean pupil dilation and maximal pupil dilation were higher during the speech-in-noise test. Mean peak dilation was measured at 3.47 ± 2.29% noise vs. 2.19 ± 2.46 in quiet and maximal peak value was detected at 9.17 ± 3.25% in noise vs. 8.72 ± 2.93% in quiet. Concerning the questionnaires, the mean pupil dilation during the retention interval was significantly correlated with the spatial subscale score of the SSQ Hearing scale [r(8) = −0.84, p = 0.0023], and with the global score [r(8) = −0.78, p = 0.0018].ConclusionThe analysis of pupillometric traces, obtained during speech audiometry in quiet and in noise in CI users, provided interesting information about the different processes engaged in this task. Pupillometric measures could be indicative of listening difficulty, phoneme intelligibility, and were correlated with general hearing experience as evaluated by the SSQ of Hearing scale. These preliminary results show that pupillometry constitutes a promising tool to improve objective quantification of CI performance in clinical settings.

Details

Language :
English
ISSN :
1662453X
Volume :
14
Database :
Directory of Open Access Journals
Journal :
Frontiers in Neuroscience
Publication Type :
Academic Journal
Accession number :
edsdoj.f2292ed7505e4a48b9728f9e623f0683
Document Type :
article
Full Text :
https://doi.org/10.3389/fnins.2020.556675